Installation
15
Access Panel
Make all connections before installing access panel.
If access panel brackets were
previously installed in Step 1,
skip A and proceed to B.
Install access panel brackets
to wall using #10 fasteners
(supplied by installer) as
A
shown in rough in drawing.
Install top screw into slot. Do
not install bottom screw until
Step C is complete.
Insert #10 thumbscrews
into front bowl apron as
B
shown. Thumbscrew in
vertical position is closed.
Thumbscrew in horizontal
position is open.
Hang access panel onto
mounting brackets attached
to the wall on the left and
right sides. Rotate panel up
and check fitup between
C
thumbscrews and panel slots.
Rotate access panel down
and make adjustment to
brackets if necessary. Install
bottom #10 fastener into
brackets.
D
Attach P-trap to drain adapter
and waste outlet.
Plug the grounding wire
E
assembly adapter from
WashBar to wall outlet.
Plug dryer power cord
from dryer motor into
GFCI protected wall outlet.
F
WashBar LEDs will light up
blue. Wait 5 seconds. Place
hands under soap dispenser,
water and dryer to be sure
all 3 functions work properly.
Check for water leaks.
Bradley • 215-1844 Rev. E; ECN 18-08-023
Shown in closed
#10
Thumb
Screw
Information
#10 Top
Screw
Rotate access panel up
G
and secure by rotating
thumbscrews to the closed
position.
For ease of installation, lift trap cover up at bottom, while positioning
over thumb screw. Start at center and move left to right.
To open access panel, rotate
thumb screw, slightly push
H
panel up and swing access
panel down. Do not remove
thumbscrews.
CAUTION For applications where
position. Rotate
90° to Open
Label
2/4/2019
LVQD3
children are present or
for applications subject to
vandalism, order security
screw option S45-2880.