1
General safety precautions
This installation manual is intended for qualified personnel only.
ROGER TECHNOLOGY cannot be held responsible for any damage or injury due to improper use or any use other than
the intended usage indicated in this manual.
Installation, electrical connections and adjustments must be performed by qualified personnel, in accordance with best
practices and in compliance with applicable regulations.
Before installing the product, make sure it is in perfect condition.
Disconnect the mains electrical power before performing any work. Also disconnect any buffer batteries used.
Only use original spare parts when repairing or replacing products.
The packaging materials (plastic, polystyrene, etc.) should not be discarded in the environment or left within reach of
children, as they are a potential source of danger.
WARNING! Handle electronic parts and terminals with extreme care, as these parts are highly sensitive to static
electricity.
2
Technical specifications
MAXIMUM NUMBER OF STORABLE USER CODES
MAXIMUM NUMBER OF DIGITS PER USER CODE
MINIMUM NUMBER OF DIGITS PER USER CODE
NUMBER OF BITS OF KEYPAD IDENTIFICATION CODE
NUMBER OF CODE COMBINATIONS
NUMBER OF BITS TRANSMITTED
TRANSMISSION FREQUENCY
MODULATION
MAXIMUM TRANSMISSION DISTANCE IN UNOBSTRUCTED ENVIRONMENT 100 m
AVERAGE POWER CONSUMPTION WITH KEYPAD ACTIVE
BATTERY
BATTERY LIFE
OPERATING TEMPERATURE
DEGREE OF PROTECTION
PRODUCT DIMENSIONS
3
Description
The H85 code-based control system enables automated motorized systems to be controlled by entering a code.
The numeric code wireless keypad is available:
• H85/TDR/E: for wall mounting (fig. 2);
• H85/TDR/I: recessed (fig. 3);
• H85/TDR/TRIX: for pillar mounting (fig. 4).
4
Functionality of the H85/TDR keypad
The H85/TDR numerical code wireless keypad consists of 12 keys, 4 of which also with a channel activation function,
for code-based access control.
Channel keys 1/A, 4/B, 7/C and */D do not have predefined functions and may be associated with an function of the
radio receiver.
It has two indicator LEDs, one green LV and one red LR (fig. 1, detail A), and a buzzer.
The red LED LR flashes during radio transmission in fixed code mode (with radio receiver H93/RX22A/I, R93/RX12A/U
and R93/RX12A/I); the green LED LV flashes during transmission in rolling code mode (with radio receiver H93/
RX2RC/I and R93/RX2RC/U).
Up to 450 user codes can be stored, each of which must have a minimum of 3 digits and a maximum of 6.
The H85/TDR wireless code keypad can manage multiple radio receivers, each of which activated with a channel key
(1/A, 4/B, 7/C and */D).
14 14
450
6
3
16 (fixed code) - 32 ("rolling code")
65536 (fixed code) - 4.294.967.296 ("rolling code)
28 (fixed code) - 144 ("rolling code")
433.92 MHz
AM/ASK
12 mA
2xCR2032
at least 2 years with 10 activations/day
-10° C
IP54
H85/TDR/I
dimensions 75x77x60 Weight: 119 g
H85/TDR/E
dimensions 75x77x41 Weight: 114 g
H85/TDR/TRIX
dimensions 75x98x58 Weight: 256 g