4. PREPARE THE HOOD
Punch out the appropriate electrical knock-out hole.
Using a long nose pliers, remove the knock-out for the chosen opening (vertical on top or horizontal at the back of the hood).
See figures below.
5. INSTALL THE ADAPTER/DAMPER
NOTE: If this hood replaces another one, please note that the location of the air exhaust can vary from one manufacturer to another.
H
,
ORIZONTAL DISCHARGE
NEW INSTALLATION
Fold down the foldable flange (C) of the
adapter/damper. This flange must be at 90° from the
remaining flanges. Use the lower screw holes on
each side of the adapter/damper to assemble it to the
back of hood. See beside.
C
HJ0006
(CONT'D)
V
:
ERTICAL DISCHARGE
HD0153
H
ORIZONTAL DISCHARGE
1
2
3
H
ORIZONTAL DISCHARGE
It may be necessary to adjust the adapter/damper location
to the existing wall discharge opening. Leave the foldable
flange (C) of the adapter/damper as is. Use the upper
screw holes on each side of the adapter/damper to
assemble it to the back of hood. See beside.
C
HJ0007
- 6 -
:
,
HOOD REPLACEMENT