Error Messages
When you turn on the fixture, it will make a reset first. The display may show "XXEr" while there are
problems with one or more channels. "XX" stands for the channels equipped with a testing sensor.
For example, when the display shows "03Er", it means there is some error in channel 3. If there are
some errors on channel 1, channel 2, channel 3 at the same time, you may see the error message
"01Er", "02Er","03Er" flash repeatly for 5 times, and then the fixture will generate a reset signal, all
the stepper motors will reset. If the error messages maintain after performing reset more than 3
times, it will detect whether the fixture has more than 3 errors. If the fixture has more than 3 errors
(including 3 errors), all the channels can not work properly; but if the fixture has less than 3 errors,
only the channels which have errors can not work properly, others can work as usual.
01Er:
(Color-wheel 1 error) This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its drive circuit on the
main PCB). The color wheel is not located in the default position after the reset.
02Er:
(Color-wheel 2 error) This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its drive circuit on the
main PCB). The color wheel is not located in the default position after the reset.
CLEANING AND MAINTENANCE
The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) Mechanically moved parts like axles, eyes and others must not show any traces of wearing (e.g. material
abrading or damages) and must not rotate with unbalances.
4) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!
The lens has to be replaced when it is obviously damaged,
so that its function is impaired, e. g. due to cracks or deep scratches!
The objective lens will require weekly cleaning as smoke-fluid tends to building up residues, reducing the
light-output very quickly. The cooling-fans should be cleaned monthly.
The dichroic colour-filters and the internal lenses should be cleaned monthly.
To ensure a proper function of the rotating parts, we recommend lubrication in six month intervals. The
quantity of oil must not be excessive in order to avoid that oil runs out when the wheel rotates.
DANGER TO LIFE!
Disconnect from mains before starting maintenance operation!
CAUTION!
42/83