G2588-180-M14
If the failure occurs while the tools is in operation, the wheel manufacturer and
the tool manufacturer should be notified promptly.
Maintenance
Rust protection and internal cleaning
Water in the compressed air, dust and wear particles cause rust and sticking of
vanes, valves etc.
This can be solved by lubricating with oil (a few drops), running the machine
for 5-10 seconds and wiping off excess oil with a cloth. Do this before longer
standstills.
Lubrication
The machine is fitted with an angle gear which is lubricated with a semi-fluid
grease to ensure good wear resistance. The grease should be refilled after about
1000 running hours.
Clean the grease nipple before refilling.
For accurate lubricating properties – use Urethyn GE00 semi-fluid type grease.
The requisite amount of grease is max. 17 cm
10 ml/ 1000 running hours. Grease gun will give 0.25 ml/ push.
Do not use ball bearing grease or chassis grease.
Excessive grease fill will result in high temperature. Excessive grease can be
drained through plug hole.
Lubricating guide
Use lubricants of good quality. The oils and greases listed in the lubrication ta-
ble are examples of lubricants that can be recommended.
Brand
BP
Castrol
Esso
Q8
Mobil
Shell
Texaco
Molycote
EN
3
. Normal grease consumption is
General purpose
Bearings
Energrease LS-EP2
Spheerol EP L2
Beacon EP2
Rembrandt EP2
Mobilegrease XHP 222
Alvania EP2
Multifak EP2
BR2 Plus
© Atlas Copco Industrial Technique AB - 9836 686400 00
Safety and operating instructions
Air lubrication
Energol E46
Arox EP46
Chopin 46
Almo oil 525
Tonna R32
Aries 32
11