⃝
Power Source
⃝
Current Consumption : Approx. 9mA max
⃝
Sleep function
⃝
Safety Standard
⃝
EMC
⃝
RoHS
⃝
Overload Protection
⃝
Withstand Voltage
⃝
Insulation Resistanc
⃝
Conductor Size
⃝
Dimensions
⃝
Weight
⃝
Accessories
⃝
Accessories
: Two R6P(DC1.5V) batteries or equivalent
: Automatically switches to the Sleep mode
in about 10 minutes after the last switch or
button operation (current consumption in
the Sleep mode: about 20
: IEC61010-1,IEC61010-2-032,IEC61010-2-033,
IEC 61010-031 pollution degree 2
overvoltage CAT.
overvoltage CAT.
: EN 61326-1
: EN 61326-2-2
: EN 55011
: EN 50581
: AC/DC current ranges 2400A AC/DC for 10sec
AC/DC voltage ranges 1200V AC/DC for 10sec
Resistance ranges 600V AC/DC for 10sec
: 6720V AC for 5 seconds
( between electrical circuit and housing
cases or metal parts of jaws)
: 10M
or greater at 1000V
Ω
( between electrical circuit and housing
cases or, metal parts of jaws)
: Approx. 55mm diameter max
: 250(L)
105(W)
×
: Approx 530g
: Test leads M-7107A
: R6P batteries
: Carrying case M-9094
: Output Plug M-8201
: Instruction manual
: Multi-Tran M-8008
: Output Lead M-7256
8
̶
̶
A)
μ
600V
Ⅳ
1000V
Ⅲ
49 (D)
×
㎜
............
........................
............
...............
..................
1set
2
1
1
1