6-7 MAX Measurement (Response time: 400ms)
The MAX measurement mode is used to display a maximum
reading over a certain period of time. This function is available on
all ranges other than
Never make measurement on a circuit in the following categories;
Measurement category
Measurement category
⃝
D o not make measurement with the battery compartment cover
removed.
⃝
D o not make measurement with the test leads connected to the
instrument.
⃝
K eep your fingers and hands behind the barrier during
measurement.
a. Set the Function Selector switch to the desired position.
b. Press the Mode button to select the MAX measurement mode.
should be shown on the display.
c. In order to take a correct reading, press the Zero Adjust/Reset
button once after clamping the jaws onto the conductor or
connecting the test leads to the circuit under test.
d. The display shows the maximum reading during measurement
e. Press the Zero Adjust/Reset button once again to return to the
normal measurement mode.
NOTE
Data Hold function is disabled in MAX measurement mode.
 ◇
For measurement over a period more than 10 minutes, disable
 ◇
the Sleep function according to the instruction in section
Sleep Function
itself off in about 10 minutes.
ranges.
Ω
DANGER
#
(CAT.
(CAT.
. Otherwise, the instrument automatically turns
̶ 
)
: over AC/DC600V
) or lower : over AC750/DCI000V
20
 ̶