Additional Safety Information - Black+Decker BEHD201 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

into account the working conditions and the
work to be performed. Use of the power tool for
operations different from those intended could result
in a hazardous situation.
5) Service
a ) Have your power tool serviced by a qualified
repair person using only identical replacement
parts. This will ensure that the safety of the power
tool is maintained.
Additional Safety Rules for Drills
Wear ear protectors when impact drilling. Exposure to
noise can cause hearing loss.
Use auxiliary handle(s), if supplied with the tool. Loss of
control can cause personal injury.
Hold power tool by insulated gripping surfaces, when
performing an operation where the cutting accessory may
contact hidden wiring or its own cord. Cutting accessory
contacting a "live" wire may make exposed metal parts
of the power tool "live" and could give the operator an
electric shock.
Use clamps or another practical way to secure and
support the work piece to a stable platform. Holding the
work by hand or against your body leaves it unstable and
may lead to loss of control.
Do not operate this tool for long periods of time. Vibration
caused by the operating action of this tool may cause
permanent injury to fingers, hands, and arms. Use gloves
to provide extra cushion, take frequent rest periods, and
limit daily time of use.
Keep your hair, clothing, and gloves away from air vents.
Air vents often cover moving parts in which these items
can be caught.
Hammer bits and tools get hot during operation. Wear
gloves when touching them.

WARNING: Shock hazard. When drilling or driving
into walls, floors or wherever live electrical wires
may be encountered, DO NOT TOUCH ANY METAL
PARTS OF THE TOOL! Hold the tool only by the plastic
handle(s) / housing to prevent shock.
Do not lock the tool ON when drilling by hand. Refer
to Operating Instructions-Switching On and Off.
Hold drill firmly with both hands to control the
twisting action of the drill (figure A). If your drill
is equipped with a side handle, always use the
side handle.

WARNING: Drill may stall (if overloaded or improperly
used) causing a twist. Always expect the stall. Grip the
drill firmly to control the twisting action and prevent
loss of control which could cause personal injury. If a
stall does occur, release the trigger immediately and
determine the reason for the stall before re-starting.
Always unplug the drill when attaching or removing
accessories. When attaching accessories in the drill chuck,
it is important to securely tighten the chuck using all three
holes to prevent slippage. When using a keyless chuck,
hand tighten firmly.

Additional Safety Information


WARNING: ALWAYS use safety glasses. Everyday
eyeglasses are NOT safety glasses. Also use face or
dust mask if cutting operation is dusty. ALWAYS WEAR
CERTIFIED SAFETY EQUIPMENT:
ANSI Z87.1 eye protection (CAN/CSA Z94.3),
ANSI S12.6 (S3.19) hearing protection,
NIOSH/OSHA/MSHA respiratory protection.

WARNING: Some dust created by power sanding,
sawing, grinding, drilling, and other construction
activities contains chemicals known to the State
of California to cause cancer, birth defects or
other reproductive harm. Some examples of these
chemicals are:
lead from lead-based paints,
crystalline silica from bricks and cement and other
masonry products, and
arsenic and chromium from chemically-
treated lumber.
Your risk from these exposures varies, depending on how
often you do this type of work. To reduce your exposure to
these chemicals: work in a well ventilated area, and work with
approved safety equipment, such as those dust masks that are
specially designed to filter out microscopic particles.
Avoid prolonged contact with dust from power
sanding, sawing, grinding, drilling, and other
construction activities. Wear protective clothing and
wash exposed areas with soap and water. Allowing
dust to get into your mouth, eyes, or lay on the skin may
promote absorption of harmful chemicals.

WARNING: Use of this tool can generate and/
or disperse dust, which may cause serious and
permanent respiratory or other injury. Always use
NIOSH/OSHA approved respiratory protection
appropriate for the dust exposure. Direct particles
away from face and body.

WARNING: Always wear proper personal hearing
protection that conforms to ANSI S12.6 (S3.19)
during use. Under some conditions and duration
of use, noise from this product may contribute to
hearing loss.

CAUTION: When not in use, place tool on its side
on a stable surface where it will not cause a
tripping or falling hazard. Some tools with large
battery packs will stand upright on the battery pack
but may be easily knocked over.
Air vents often cover moving parts and should be
avoided. Loose clothes, jewelry or long hair can be
caught in moving parts.
An extension cord must have adequate wire size
(AWG or American Wire Gauge) for safety. The smaller
the gauge number of the wire, the greater the capacity
of the cable, that is, 16 gauge has more capacity than 18
gauge. An undersized cord will cause a drop in line voltage
resulting in loss of power and overheating. When using
more than one extension to make up the total length,
be sure each individual extension contains at least the
English
3

Publicidad

Tabla de contenido
loading