CAUTION ! Do not use the power cord to lift the pump.
ES
Make sure that the pump is installed upright and stable.
Pump needs at least 46mm of water to work. Plug in the electrical outlet.
PT
IT
• Operate the product only at reasonable hours – not early in the morning or late at night
EL
when people might be disturbed.
• Do not modify the product in any way or use parts and accessories that are not
PL
recommended by the manufacturer.
RU
KZ
UA
RO
Stop the pump
• To reduce the risk of injury, always stop the machine :
EN
- before cleaning or clearing a blockage
- when leaving the product unattended
- before installing or removing attachments
- before checking, maintaining or working on the product
- if the machine starts to vibrate abnormally (inspect immediately)
4.5 SPECIFIC FUNCTIONS
Dry run protection function : illustration 3.i
This unit detects the presence of water in the suction hose. In case of absence of water at the inlet, the
system stops itself in order to protect the machine from "dry running". After the first stop, the unit will
automatically try to restart and drain the water. In case of failure, the pump will restart (and try to drain
again) at the following time intervals :
• t0 + 4 min
• t0+ 1h
• t0+ 6h
• t0+ 26h
Note : The pump will start automatically after plugging the
cable outlet.
If the product is dropped, suffers heavy impact or begins to
vibrate abnormally, immediately stop the product and
inspect for damage or identify the cause of the vibration.
Any damage should be properly repaired or replace by an
authorized service center.
Note : You can interrupt the Dry Running Protection cycle at
any time and use the pump normally by disconnecting and
reconnecting the powerplug. (Make sure there is water in the
suction hose)