SHAKING WATER BATH
WBS-300
1. Introduction
Thank you for purchasing this piece of
Cole-Parmer equipment. To get the best
performance from the equipment please read
these instructions carefully before use.
Before discarding the packaging check that all
parts are present and correct.
For your own safety and that of others
please read and understand the safety
advice given below before using the
equipment.
2. General Description
The Cole-Parmer WBS-300 shaking water bath is
the ideal instrument for mixing, gently heating
and aerating biological and chemical samples in
the laboratory. The unique design allows a
choice of either linear or orbital mixing action,
depending on the application. Both platforms
will accommodate up to 15 springs, which will
hold almost any size and combination of flasks,
bottles or beakers. Max load for both platforms
is 10kg.
3. Safety Advice before use
If the equipment is not used in the manner
described in this manual and with
accessories other than those recommended by
Antylia Scientific the protection provided might
be impaired.
This equipment is designed to operate under the
following conditions: -
❖ For indoor use only
❖ Use in a well ventilated area
❖ Ambient temperature range +5°C to +40°C
❖ Altitude to 2000m
❖ Relative humidity not exceeding 80%
❖ Mains supply fluctuation not exceeding 10%
❖ Over-voltage category II IEC60364-4-443
❖ Pollution degree 2
❖ Use with a minimum distance all around of
200mm from walls or other items
❖ DO NOT mix combustible liquids or use the
equipment in hazardous atmospheres.
❖ When empty the unit should be carried using
both hands.
❖ The unit is designed for use with aqueous
liquids. It may be dangerous to use other
liquids (especially inflammable substances) in
the bath.
❖ Do not attempt to stop movement by hand.
❖ Never move or carry the unit when in use or
connected to the mains electricity supply.
❖ In the case of mains interruption, the unit will
not restart on restoration of the electricity
supply.
❖ In the case of mechanical interruption, (e.g.
motor stall), the unit will continue operating
on removal of interruption.
❖ Mechanical energy can lead to breakage of
glass vessels. Use with care.
❖ DO NOT position the product so that it is
difficult to access the ON/OFF switch.
❖ DO NOT position the product so that it is
difficult to disconnect it from the mains
supply using the mains plug.
❖ The mains outlet socket used should be
located close to the equipment and readily
identifiable and accessible to users.
Never move or carry the unit when filled
with water.