Switch action
WARNING:
Before installing the battery car-
tridge into the tool, always check to see that the
switch trigger actuates properly and returns to
the "OFF" position when released.
WARNING:
Do not attach a tape or such to
keep the switch trigger in the "ON" position.
To start the tool, simply pull the switch trigger. Release
the switch trigger to stop.
1
► 1. Switch trigger
Pressure gauge
1
2
3
4
5
1
2
3
4
5
6
7
6
7
8
9
Overheat warning icon
Inflation mode
[-] button
[M] button
[+] button
Inflation progress indicator
Current pressure value
8
9
If the object to be inflated is connected to the tool, the
current pressure value of the object is displayed on the
pressure gauge when you turn on the tool. If nothing is
connected to the tool, the pressure gauge displays "0".
The pressure gauge also displays the target pressure
value, pressure value unit, and inflation mode. They are
the same as the last time.
When you start inflation, the inflation progress indicator
is displayed. The inflation completes when the inflation
progress indicator comes to the right end.
Setting the target pressure value
Press the [M] button, and select the pressure value unit.
The pressure value unit is changed each time you press
the [M] button. You can select one of the three units:
PSI, BAR, or KPA.
To increase the target pressure value, press the [+] but-
ton. To decrease the target pressure value, press the [-]
button. You can set the target pressure value between
35 kPa (5 PSI) and 1,100 kPa (160 PSI).
Setting the inflation mode
Press the [M] button for 3 seconds. The inflation mode
is changed each time you press and hold the [M] button.
You can select one of the three modes as follows.
Mode
Display
Ball
Low speed
High speed
NOTE: Be sure to select the ball mode when you
inflate a ball using a sport ball needle. If other mode is
selected, the inflation cannot be performed properly.
NOTE: Be sure to select the low speed mode when
you inflate an object using an English valve adapter. If
other mode is selected, the inflation cannot be per-
formed properly.
7 ENGLISH
Target pressure value
Pressure value unit
Purpose
Adjustable
pressure
range
To inflate
35 to 110 kPa
balls
(5 to 16 PSI)
To inflate
35 to 1,100
objects in low
kPa
speed
(5 to 160 PSI)
To inflate
objects in
high speed