6
Position at least one person at the front of the enclosure and one person at the rear of the
enclosure. Slowly push the enclosure toward the back of the shipping pallet until all four casters
go over the edge of the pallet and touch the floor.
WARNING: Use at least one assistant when removing the enclosure from the pallet. Be
extremely careful when moving the enclosure.
4.3 Placement
1
Use the casters to move the enclosure for a short distance over a level, smooth, stable surface by
pushing it from the front or rear (not the side panels). Do not attempt to roll the enclosure over
long distances. The enclosure should be moved close to its installation location inside its shipping
container before it is unpacked. (Use a forklift or pallet jack to move the shipping container.)
WARNING: Do not push or pull the enclosure at the side panels or pull the enclosure
toward you.
If required, the enclosure can be lifted by attaching 4 user-supplied M8 diameter eye bolts to the threaded holes near the upper corners of the enclosure
frame. Use steel bolts with an ISO strength rating of 8.8 or higher. The 4 bolts can support the weight of the enclosure and up to 1000 lb (450 kg) of
installed equipment.
WARNING: Only experienced equipment operators should attempt to lift the enclosure. Use appropriate equipment and follow all applicable
safety procedures and regulations.
4.4 Leveling
WARNING: Level the enclosure before attempting to install equipment. The casters are not designed to provide long-term support for the
enclosure. Use the levelers to provide long-term support. Install the enclosure in a structurally sound area with a level floor that is able to bear
the weight of the enclosure, all equipment that will be installed in the enclosure and any other enclosures and/or equipment that will be
installed nearby.
1
After the enclosure has been moved to the installation location, use a carpenter's level to check
the slope of the floor. If the floor slopes more than 1%, choose an alternate installation site.
2
Use an 18 mm open-end wrench to lower each leveler
levelers, 2 at the front and 2 at the rear.) Make sure each leveler contacts the floor solidly.
Note: Lower a leveler by turning it clockwise; raise a leveler by turning it counter-clockwise.
3
After lowering each leveler, use the carpenter's level to confirm that the enclosure is level in all
directions. Adjust the levelers as required until the enclosure is level.