Descargar Imprimir esta página

Cooper Lighting HALO TGS3S401DSRB Manual De Instrucciones página 2

Publicidad

Idiomas disponibles

Idiomas disponibles

MOUNTING AND WIRING YOUR FIXTURE
WARNING: Risk of electric shock. Disconnect
power at fuse or circuit breaker before installing
or servicing.
NOTE: Fixture can be wall or eave mounted (Fig. 2).
NOTE: Mounting bracket mounts to recessed mounted
standard junction boxes (Fig. 3). Junction box must be
at least 1-1/2 inch in depth for proper installation for
recessed mount application. For surface mount junction
box installation, refer to installation instructions included
with the adapter plate kit (E).
1. Line up the slots on the mounting bracket (B) with
the holes on your junction box. Using either (2)
#6 screws or (2) #8 screws (D) (depending on
size of the holes in your junction box), attach the
mounting bracket (B) to your junction box (Fig. 4).
Be sure the mounting bracket is installed with the
funnel for the central mounting screw going into
the junction box.
2. Make the electrical connection between the
ground wire on the mounting bracket and the
ground wire inside of the junction box.
3. Disconnect the male connector in the back of the
fixture. Insert the junction box wires to the male
connector while ensuring the hot wire (black)
and neutral wire (white) are connected to the cor-
responding black and white connections on the
male connector. (Fig. 5)
Note: Be sure these are solid wires and stripped
3/8".
3/8"
4. Plug the male connector into the female connec-
tor through the gasket (C). Rotate the connector
so it is recessed within the back surface of the
fixture. (Figs. 6 & 7)
5. Attach fixture (A) to the mounting bracket (B)
using the central mounting screw that is already
installed in the fixture. Be sure no loose wires re-
main sticking out from underneath the coverplate.
Insert the decorative screw cover cap (F) into
the screw hole on the coverplate for a finished
appearance (Fig. 8).
6. Adjust light fixture to desired position by loosen-
ing the thumbscrew on the upper arm. Move the
head to aim and retighten the thumbscrew.
7. Apply silicone caulk around the edges of the
canopy to provide a watertight seal from rain and
moisture.
8. Turn on power at main fuse/breaker box.
6
7
FIG.6
Supplier's Declaration of Conformity
47 CFR § 2.1077 Compliance Information
Unique Identifier: Security Gen 3 Light
FIG.6
Responsible Party – U.S. Contact Information
Cooper Lighting Solutions
1121 Highway 74 S
Peachtree City, GA
30269
www.cooperindustries.com/content/public/en/lighting.html
FCC Compliance Statement
This device complies with Part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
2
Wall mount
Wall Mount
Eave Mount
3
Eave mount
1-1/2 in.
FIG.3
Round
FIG.3
4
B
D
D
FIG.4
5
FIG.6
8
C
A
B
Screw Cover Cap
F
FIG.7
FIG.9
TROUBLESHOOTING
Wall mount
Problem
Light does not
come ON.
Eave mount
FIG.3
Light cycles ON
1-1/2 in.
and OFF
continuously.
Light stays ON.
Octagonal
Junction box
5-YEAR LIMITED WARRANTY
THE FOLLOWING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES,
WHETHER EXPRESS, IMPLIED OR STATUTORY INCLUDING, BUT NOT LIMITED TO, ANY
WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE.
Cooper Lighting Solutions warrants to customers that, for a period of five years from the date
of purchase, Cooper Lighting Solutions products will be free from defects in materials and
workmanship. The obligation of Cooper Lighting Solutions under this warranty is expressly
limited to the provision of replacement products. This
B
warranty is extended only to the original purchaser of the product. A purchaser's receipt or
other proof of date of original purchase acceptable to Cooper Lighting Solutions. This is re-
quired before warranty performance shall be rendered. This warranty does not apply to Coo-
A
per Lighting Solutions products that have been altered or repaired that have been subjected
to neglect, abuse, misuse or accident (including shipping damages). This warranty does not
apply to products not manufactured by Cooper Lighting Solutions which have been supplied,
installed, and/or used in conjunction with Cooper Lighting Solutions products. Damage to the
product caused by replacement bulbs or corrosion or discoloration of brass components are
not covered by this warranty.
LIMITATION OF LIABILITY:
IN NO EVENT SHALL COOPER LIGHTING SOLUTIONS BE LIABLE FOR SPECIAL, INDIRECT,
INCIDENTAL, OR CONSEQUENTIAL DAMAGES (REGARDLESS OF THE FORM OF ACTION,
WHETHER IN CONTRACT, STRICT LIABILITY, OR IN TORT INCLUDING NEGLIGENCE), NOR
FOR LOST PROFITS; NOR SHALL THE LIABILITY OF COOPER LIGHTING SOLUTIONS FOR ANY
CLAIMS OR DAMAGE ARISING OUT OF OR CONNECTED WITH THESE TERMS OR THE MANU-
FACTURE, SALE, DELIVERY, USE, MAINTENANCE, REPAIR OR MODIFICATION OF COOPER
LIGHTING SOLUTIONS PRODUCTS, OR SUPPLY OF ANY REPLACEMENT PARTS THEREFORE,
EXCEED THE PURCHASE PRICE OF COOPER LIGHTING SOLUTION PRODUCTS GIVING RISE
TO A CLAIM. NO LABOR CHARGES WILL BE ACCEPTED TO REMOVE OR INSTALL FIXTURES.
To obtain warranty service, please contact Cooper Lighting Solutions, at 1-800-334-6871,
press option 2 for Customer Service, or via e-mail ConsumerProducts@cooperlighting.com
Central Mounting
and include the following information:
Screw
• Name, address and telephone number
• Date and place of purchase
• Catalog and quantity purchase
• Detailed description of problem
All returned products must be accompanied by a Return Goods Authorization Number issued
by the Company and must be returned freight prepaid. Any product received without a Return
Goods Authorization Number from the Company will be refused. Cooper Lighting Solutions is
not responsible for merchandise damaged in transit. Repaired or replaced products shall be
subject to the terms of this warranty and are inspected when packed. Evident or concealed
damage that is made in transit should be reported at once to the carrier making the delivery
and a claim filed with them.
Reproductions of this document without prior written approval of Cooper Lighting Solutions are strictly prohibited.
For assistance, call 1-800-334-6871 or e-mail us at ConsumerProducts@cooperlighting.com
Printed in China
FRENCH
ARTICLES REQUIS:
(à acheter séparément)
• Tournevis cruciforme
• Calfeutrage en silicone étanche pour l'extérieur
2
Cause / Solution
No power to the fixture.
• Check if circuit breaker tripped.
• Confirm wall switch is ON.
TURN OFF POWER BEFORE CONTINUING
Wiring to the unit is loose.
• Confirm wiring is properly secured.
* If light still does not come on after checking wiring
connections, contact Customer Service.
Light sensor is sensing reflected light.
• Relocate light fixture where it no longer cycles on and off
Light sensor is in a shaded area.
• Shine a flashlight into the light sensor. If the light turns off,
the fixture is mounted in an area that does not allow enough
light to enter the light sensor.
If light sensor is not in a shaded area, light sensor could be
faulty.
• Contact Customer Service.

Publicidad

loading

Este manual también es adecuado para:

Halo tgs3s401dsrwHalo tgs2s402drrbHalo tgs2s402drrwHalo tgs2s402dsrbHalo tgs2s402dsrwHalo tgs3s403drrb ... Mostrar todo