Descargar Imprimir esta página

Quick BXS 40 Manual Del Usuario página 15

Ocultar thumbs Ver también para BXS 40:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 28
POS. DESCRIPTION
1A
Tank 25l
1B
Tank 40l
2
Red plastic washer
3
White plastic washer
4
Blue plastic washer
5
Relief/non return valve
6
Hose clamp
7
Discharge pipe
8 A
Element gasket
from S/N 100.000
8 B
Element gasket
from S/N 200.000
9A
Electric element
1200W 220V
9B
Electric element
500W 220V
9C
Electric element
1200W 110V
9D
Electric element
600W 110V
10
Bi-Thermostat
11
Power supply cable
12A
Boiler resistor cover 220V
12B
Boiler resistor cover 110V
13
Nut
14
Ground cable terminal
15
Washer
16
Screw 2,9 x 19
BOILER BXS 25-40 - REV006A
CODE
SAMLB25320S0
SAMLB40360S0
PECRBLRS0000
PECRBLBNC000
• shut down power supply.
PECRBLBL0000
• Remove the protection cover (12) in order to reach
the thermostat (10).
MNVALS12S68P
• Push the reset button on the double thermostat (fi g. 4).
PBF25100W000
• Replace on the protection cover (12).
PVTBGM10NT00
• Switch on power supply.
PGGRES000000
PGRM43500000
EVR12220N000
MAINTENANCE
EVR05220N000
We recommend checking the magnesium anode (A) every
EVR12110N000
12 months.
Replace the anode if its size has been reduced signifi cantly.
EVR06110N000
This simple and preventive maintenance will ensure a long
EVT15S000000
life of the equipment.
ECC30150G000
PECRB2200000
F
PECRB1100000
MBD04MXEN000
ESCL04000000
MBR04X000000
The overpressure release device must be activated regu-
MBV02919AXCC
larly to remove calcium deposits and to ensure that it is not
blocked.
Periodically check the joints of the water pipe installation;
check the tightness of the securing screws and replace
them in case they are worn or corroded.
Also periodically check the electrical system working order.
MAINTENANCE
WARNING: Quick
®
nautic water heaters are provided
with a double thermostat with manual reset that
shuts down power supply in case of an excessive
water temperature.
If it happens, follow the instructions below:
WARNING: if the high temperature safety system
switches on repeatedly, call Quick
During wintertime, when the water heater is not
in use it should be drained using the lever of the
valve (5). This is to avoid serious damage caused by
freezing.
GB
®
service center.
15

Publicidad

loading

Este manual también es adecuado para:

Bxs 25