TECHNICAL SPECIFICATIONS

Input voltage (U1)
Maximum input current (I1 máx)
No-load voltage (U0)
Max. absobed power
Fuse
Mig-Mag regulation range
MMA regulation range
TIG regulation range
Mig-Mag duty cycle
MMA duty cycle
TIG duty cycle
Usable wires of Fe
Usable wires of Ss
Usable wires of Al
Maximum feeding speed
Rollers
Power of the motor
Maximum spot time
Temperature protection class
IP protection class
Ventilation
Weight
Dimensions
Standards
The machine is designed to be used outdoors. However, it should be protected from rainfall while it's in use.
PROTECTION
The machine features all necessary protective measures to ensure proper operation. Temperature sensors ensure
that the components are kept within the operating range.
Monitoring of the supply voltage ensures that the machine operates within expected ranges and, in case of excee-
ding them, is disconnected to prevent possible anomalies.

OPERATING CYCLE AND OVERHEATING

The operating cycle is the percentage of 10 minutes during which the unit can weld at the required power without
overheating. If machine becomes overheated, the welding power will stop. The screen will display an alarm showing
which internal module is the one that has been overheated. The fans turn until the internal temperature is below
40°C. The machine will automatically reset when it reaches a safe temperature again. However, it is recommended to
wait at least 5 minutes before starting to work normally again.
To avoid overheating, reduce the adjusted welding power or the length of the welds.
If the nominal operating cycle of the machine is exceeded and the equipment is forced to work for too
long (without being allowed to cool properly), this could cause significant damage not covered by the
SOLTER
SOLDADURA S.L.
Aeroprocess 2000
Aeroprocess 3200
230V +/- 15%
37A
68V
9KVA
25A
30-200A
10-200A
10-220A
200A 45% (40ºC)
200A 68% (20ºC)
200A 45% (40ºC)
200A 68% (20ºC)
250A 100% (20ºC)
220A 45% (40ºC)
220A 72% (20ºC)
250A 100% (20ºC)
0,6 - 0,8 - 1,0 - 1,2
0,6 - 0,8 - 1,0 - 1,2
0,8 - 1,0 - 1,2
1,0 - 1,2
11m/min
2R
30W
10s
H (180ºC)
IP23S
FORCED
19 Kg
Aeroprocess 2000
Aeroprocess 3200
407x602x285mm
IEC 60974-1 / EC 60974-10
ATTENTION
guarantee.
AEROPROCESS
Aeroprocess 3220
400V +/- 15%
22,2A
64V
9KVA
20A
30-320A
10-250A
10-250A
320A 40% (40ºC)
320A 40% (40ºC)
320A 60% (20ºC)
320A 60% (20ºC)
250A 60% (40ºC)
250A 60% (40ºC)
250A 100% (20ºC)
250A 60% (40ºC)
250A 60% (40ºC)
250A 100% (20ºC)
0,6 - 0,8 - 1,0 - 1,2
0,8 - 1,0 - 1,2
1,0 - 1,2
18m/min
4R
65W
10s
H (180ºC)
IP23S
FORCED
58 Kg
Aeroprocess 3220
808x935x308
400V +/- 15%
22,2A
64V
9KVA
20A
30-320A
10-250A
10-250A
0,8 - 1,0 - 1,2
1,0 - 1,2
18m/min
4R
65W
10s
H (180ºC)
IP23S
FORCED
56 Kg
808x935x308
4