ROLLERS
ROLLERS
0,6 - 0,8 V groove
0,8 - 1,0 V groove
1,0 - 1,2 V groove
1,2 - 1,6 V groove
0,8 - 1,0 U groove
1,0 - 1,2 U groove
1,2 - 1,6 U groove
0,8 - 1,0 Knurled groove
1,0 - 1,2 Knurled groove
1,2 - 1,6 Knurled groove
FAULTS
In the event of any fault that may be hazardous to people, the machine and/or the environment, you must disconnect
the machine immediately and make sure it cannot be reconnected until the problem that caused the fault has been
solved. Faults should only be eliminated by qualified personnel, taking into account the safety instructions of the ma-
chine.

POSSIBLE ANOMALIES AND SOLUTIONS

ANOMALY
The machine doesn't start up
Anomaly indicator lights up
Overtemperature indicator lights up
Output indicator is flashing
The wire does not come out correctly
The wire does not come out at the
proper speed
Shielding gas doesn't comes out
The arc is not stable and the wire
collides with the workpiece.
SOLTER
SOLDADURA S.L.
MATERIAL
Fe, SS,CuSi, CuAl
Fe, SS,CuSi, CuAl
Fe, SS,CuSi, CuAl
Fe, SS,CuSi, CuAl
Al
Al
Al
Flux Core, Metal Core
Flux Core, Metal Core
Flux Core, Metal Core
POSSIBLE CAUSE
Verify the mains
Defective main switch.
Turn off the machine or unplug it from the mains for 1 minute and try to
start it up again.
Electronic circuit is defective.
Turn off the equipment for a minute and start it up again. If the error
persists, contact technical service.
The machine has become overheated. Wait until the machine regains a
safe temperature.
The equipment has found that the torch push button was pressed du-
ring startup or when recovering from an overtemperature fault. Release
the button of the torch and/or pedal.
Verify that the drive system rotates correctly.
Verify that the coil brake is not too tight.
Verify that the drive system accessories are in good conditions.
Verify that the torch and consumables are in good conditions.
At the beginning of the welding, the wire always comes out with a mini-
mum speed. Verify that the wire feeding system works properly with the
manual feeding
button.
Check that there is gas in the bottle.
Check that the flow rate adjustment is correct.
Verify that torch is not pinched and / or perforated.
Gas valve defective.
Check if the material used corresponds to the selected in the machine.
Verify that consumables and rollers are appropriate with the material in
use.
AEROPROCESS
2000
3200
56105
-
56106
55600
55986
55601
-
55602
55987
55612
55988
55603
-
-
56116
-
55989
55604
-
55605
3220
55606
-
55607
55608
-
55609
55610
-
55611
55613
EN
19

Hide quick links:

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Aeroprocess 3200Aeroprocess 3220

Tabla de contenido