Descargar Imprimir esta página

Cameo F1 FC Manual De Usuario página 4

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 54
32. The device must only be installed in a voltage-free condition (disconnect the mains plug from the mains).
33. Dust and other debris inside the unit may cause damage. The unit should be regularly serviced or cleaned (no guarantee) depending on
ambient conditions (dust etc., nicotine, fog) by qualified personnel to prevent overheating and malfunction.
34. Please keep a distance of at least 0.5 m to any combustible materials.
35. Power cables to power multiple devices must have a cross-section of at least 1.5 mm². Within the EU, the cables must correspond to
H05VV-F, or similar. Suitable cables are offered by Adam Hall. With these cables, you can connect multiple devices via the power OUT
connection to the power IN connection of an additional device. Make sure that the total current consumption of all connected devices does not
exceed the specified value on all connected devices (label on the device). Make sure to keep power cable connections as short as possible.
The warning triangle with lightning symbol indicates dangerous uninsulated voltage inside the unit, which may cause an
electrical shock.
The warning triangle with exclamation mark indicates important operating and maintenance instructions.
Warning! This symbol indicates a hot surface. Certain parts of the housing can become hot during operation. After use, wait for
a cool-down period of at least 10 minutes before handling or transporting the device.
Warning! This device is designed for use below 2000 metres in altitude.
Warning! This product is not intended for use in tropical climates.
Caution! Intense LED light source! Risk of eye damage. Do not look into the light source.
CAUTION! IMPORTANT INFORMATION ABOUT LIGHTING PRODUCTS!
1. Do not stare, even temporarily, directly into the light beam.
2. Do not look at the beam directly with optical instruments such as magnifiers.
3. Stroboscope effects may cause epileptic seizures in sensitive people! People with epilepsy should definitely avoid places where
strobes are used.
INTRODUCTION
CONTROL FUNCTIONS
1 channel, 2 channel DIM, 2 channel CCT, 3 channel RGB, 4 channel RGBW, 4 channel CCT, 6 channel HSI/CCT, 7 channel RGB/CCT, 8
channel RGBW 16Bit, 10 channel HSI/CCT, 16 channel RGBW/CCT 16Bit
Master / slave mode
Stand-alone functions
PROPERTIES
1x high power 124 W RGBW LED. 15.2° to 51.1° beam angle, manual zoom. 150 mm Fresnel lens. Configurable PWM frequency (flicker
free). DMX-512 control. RDM enabled. Manual control. 4 dimmer curves. 16-bit dimming. Master/slave mode. Extremely quiet operation
thanks to heat pipe cooling and fan. Operating voltage: 100–240 V AC / 50–60 Hz. Power consumption: 128 W. Mounting bracket, filter
frame, and 8-way barn door included. DC input for battery operation (11–17 V). Adapter for V-mount batteries optionally available.
The spotlight complies with the RDM standard (Remote Device Management). This device manager allows the user to request the status of
and configure RDM end devices via an RDM-capable controller.
4
CAUTION:
To reduce the risk of electric shock, do not remove cover (or back). There are no user serviceable
parts inside. Maintenance and repairs should be exclusively carried out by qualified service
personnel.

Publicidad

loading

Este manual también es adecuado para:

Clf1fc