CONNECTING DISPOSER TO SINK FLANGE
ATTACH TO SINK FLANGE
1
Line up the disposer
under the sink flange.
Guide the hopper
projections into the
mount ring slots. Turn
the mount ring about
1/4" to the right so
that the disposer is
temporarily supported.
LINE UP WITH OUTLET PIPE
2
Turn the mount ring and the disposer until the
disposer discharge elbow lines up with the outlet
pipe (see page 8).
Discharge
Elbow
Outlet Pipe
Installation Instructions
Mount
Ring Slot
Hopper
Projection
LOCK MOUNT RING
3
Turn the mount ring to the right until it locks up
tight. Hopper projections must be to the extreme
left of the mounting slots. If the mount ring is
hard to turn, you may add a small amount of
petroleum jelly or liquid soap to the hopper
projection. Run water and check for leaks.
Locking Detail
Hopper Projection in
"Supported" Position
Hopper Projection in
"Locked" Position
CHECK FOR LEAKS
4
Check the unit for leaks 24 hours after installation
and first operation.