16 INSTALLATION
Installing the Anti-tip Device
Screw must
enter wood or
concrete
The anti-tip bracket is packaged with an installation
template. The instructions include necessary
information to complete the installation. Read and
follow the range installation instruction sheet.
WArnInG
• Range must be secured with an approved anti-tip
device.
• The range could be tipped by standing, sitting or
leaning on an open door if the range or anti-tip
device is not properly installed.
• After installing the anti-tip device, verify that it is in
place by carefully attempting to tilt the range forward.
• This range has been designed to meet all recognized
industry tip standards for all normal conditions.
• The installation of the anti-tip device must meet all
local codes for securing the appliance.
• The use of this device does not preclude tipping of
the range when not properly installed.
• A child or adult can tip the range and be killed.
• Install the anti-tip device to the structure and/or the
range. Verify the anti-tip device has been properly
installed and engaged by following the guide of the
Anti tip bracket template.
• Engage the range to the anti-tip device by following
the guide of the Anti tip bracket template. Ensure
the anti-tip device is re-engaged when the range is
moved by following the guide of the Anti tip bracket
template.
• Re-engage the anti-tip device if the range is
moved. Do not operate the range without the anti-
tip device in place and engaged.
• See installation instructions for details.
• Failure to do so can result in death or serious
burns to children or adults.
Optional rear Filler
If the counter does not bridge the opening at the rear
wall the rear filler kit, that is provided with the slide in
range, will be needed.
nOTE
If the countertop depth is greater than 25" there will
be a gap between the filler kit and the back wall.
If the countertop depth is less than 24", the control
panel will not sit flush with the countertop.
Anti-tip
Wall plate
bracket
Installing the rear Filler
1
Using a screwdriver, remove the three screws
holding the rear bracket in place.
Rear bracket
2
Attach the rear bracket and filler assembly as
shown, using the three screws removed in
step 1.
Rear filler
Providing Adequate Gas
Supply
Your range is designed to operate at a pressure of
5" of water column on natural gas or 10" of water
column on LP.
Make sure you are supplying your range with the type
of gas for which it is configured.
This range is convertible for use on natural or LP gas.
When using this range on LP gas, conversion must
be made by a qualified LP installer before attempting
to operate the range.
For proper operation, the pressure of natural gas
supplied to the regulator must be between 5" and 13"
of water column.
For LP gas, the pressure supplied to the regulator
must be between 10" and 13" of water column. When
checking for correct operation of the regulator, the
inlet pressure must be at least 1" more than the
operating (manifold) pressure as given above.
The pressure regulator located at the inlet of the
range must remain in the supply line regardless of
which type of gas is being used.
A flexible metal appliance connector used to connect
the range to the gas supply line should have an I.D.
of
/
" and a maximum length of 5 feet. In Canada,
5
8
flexible connectors must be single wall metal
connectors less than 6 feet in length.