Cleansing and Care
• It is very important to clean the spray gun thoroughly
after each use.
WARNING
An inadequate cleansing can result in
malfunctioning and will cancel the Warranty.
• Turn the jar to remove it from the gun. Do not remove
completely. Press the trigger to remove remaining product
from inside the spray gun system (A).
• Pour the remaining material into an adequate container.
• Disconnect the paint gun hose.
• Clean the jar, the gasket seal and the suction pipe
thoroughly with a rag soaked with the solvent that is right
for the product.
• Disassemble the regulator, the sprayer, the nozzle and
the needle. Clean them with a brush and solvent.
• Clean the paint gun body with a piece of rag moistened
with solvent.
CAUTION
Do not immerse the gun in solvent. The
gasket may get damaged.
• When the parts are clean assemble back the spray gun.
• Pour a small amount of solvent into the jar.
• Connect the hose to the spray gun.
• Start the compressor and spray into a container until
getting clean solvent out through the nozzle.
Needle Seal
• Use special care adjusting the needle seal. This is very
important to obtain good results.
• Adjust the needle seal using a wrench (B).
• Periodically check the seal to be sure it is not damaged.
To gain access to the seal remove the needle and remove
the seal pressing piece (C).
8
ENGLISH
Maintenance
A
B
C