WINDOW REQUIREMENTS
1
• These instructions are for a standard
double-hung window. You will need to modify
them for other types of windows.
• All supporting parts must be secured to firm
wood, masonry or metal.
• The electrical outlet must be within reach
of the power cord.
• Follow the dimensions in the table and
illustration for your model.
Models
ASQ05, ASS05, ASV05
ASQ06, ASV06
ASM05, ASM06
ASQ08, ASV08
(With accordion panels)
Installation Instructions
A
B
11 3/4" min.
22"–36"
13" min.
22"–36"
13 1/2" min.
22"–36"
13 1/2" min.
24 1/2"–36"
A
B
STORM WINDOW REQUIREMENTS
2
A storm window frame will not allow the air
conditioner to tilt toward the outside, and will
keep it from draining properly. To adjust for
this, attach a piece of wood to the sill.
WOOD PIECES –
WIDTH: 2"
LENGTH: Long enough to fit inside the
window frame.
THICKNESS: To determine the thickness,
place a piece of wood on the sill to make
it 1/2" higher than the top of the storm
window frame or the vinyl frame.
Attach securely with nails or screws
provided by the installer.
1/2" higher
than storm
window
frame
Storm window
frame
PREPARE AIR CONDITIONER
3
Remove the backing from the top
A
mounting rail seal strip and attach it
to the bottom of the top mounting rail.
Cut to size.
Install the top mounting rail with 3 or 4
B
type A screws (depending on the number
of holes in the top mounting rail) from the
outside of the case.
Top mounting
rail
Bottom
mounting rail
11
1/2" higher
than vinyl frame
(on some windows)
Wood
Sill
Vinyl frame

Publicidad

loading