4.3 Hood transition
Discharge direction
The exhaust air is discharged upwards through a duct or
directly through the outside wall into the open.
The hood can be mounted on the wall only with a vertical
discharge.
Attaching the hood transition
Your hood is supplied with a 10" (254 mm) round
transition. A locally supplied transition is required for other
sizes.
A minimum height clearance of 7⁷⁄₁₆" (189 mm) is
1.
needed above the hood for transition mounting.
Align the mounting holes at the base of the transition
2.
over the mounting holes of the ½" (13 mm) flange
located at the top of the hood.
Fasten the transition to the hood using four (4) ¼"
3.
(6 mm) sheet metal screws included with the hood.
Note: Make sure the screws do not hinder the damper
operation.
Seal the connection between transition and hood with
SKU
4.
aluminum tape. DO NOT use duct tape. Ensure that the
EXTNCB25W
connection is completely sealed.
Remove the tape that is holding the damper closed.
5.