TABLE "A" - PARAMETERS MENU - (PARA )
Parameter
min.
max.
OPEN DELAY
0
10
TI E
CLS DELAY
0
25
TI E
0
120
TCA
1
180
TRF. L GHT. C LR. T
0
50
OP. D IST. S LOUD
0
50
CL. D IST. S LOUD
0
50
DIST. D ECEL
1
99
OP. F ORCE
1
99
CLS. F ORCE
15
99
OP SPEED
15
99
CL SPEED
SLOW SPEED
15
99
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
34 -
THALIA P
INSTALLATION MANUAL
Default
Personal
Definition
Motor 2 opening delay
1
time [s]
Motor 1 closing delay
1
time [s]
Automatic closing time
10
Time-to-clear traffic light
40
Slow-down distance
10
during opening [%]
Slow-down distance
10
during closing [%]
Deceleration distance
15
Leaf force during
50
opening [%]
Leaf force during
50
closing [%]
99
Opening speed [%}
99
Closing speed [%]
25
Slow-down speed [%]
Motor 2 opening delay time with respect to motor 1.
Motor 1 closing delay time with respect to motor 2.
Waiting time before automatic closing.
[s]
Time-to-clear for the zone run through by traffic controlled by the traffic
zone [s]
light.
Slow-down distance for motor(s) during opening, given as a percentage
of total travel. WARNING: Once the parameter has been edited, a
complete uninterrupted opening- closing c ycle is required.
WARNING: when the display reads "SET", obstacle detection is not active.
Slow-down distance for motor(s) during closing, given as a percentage
of total travel. WARNING: Once the parameter has been edited, a
complete uninterrupted opening- closing c ycle is required.
WARNING: when the display reads "SET", obstacle detection is not active.
Deceleration distance (switch from running speed to slow-down
speed) for motor(s) both during opening and during closing, given as a
percentage of total travel. WARNING: Once the parameter has been
[%]
edited, a complete uninterrupted opening-closing cycle is required.
WARNING: when the display reads "SET", obstacle detection is not active.
Force exerted by leaf/leaves during opening. This is the percentage of force
delivered, beyond the force stored during the autoset cycle (and subsequently
updated), before an obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current
safety requirements are met with the set value (*). Install anti-
crush safety devices where necessary.
Force exerted by leaf/leaves during closing. This is the percentage of force
delivered, beyond the force stored during the autoset cycle (and subsequently
updated), before an obstacle alarm is generated.
The parameter is set automatically by the autoset function.
WARNING: It affects impact force directly: make sure that current
safety requirements are met with the set value (*). Install anti-
crush safety devices where necessary.
Percentage of maximum speed that can be reached by motor(s) during
opening. WARNING: Once the parameter has been edited, a complete
uninterrupted opening-closing cycle is required. WARNING: when the
display reads "SET", obstacle detection is not active.
Percentage of maximum speed that can be reached by motor(s) during
closing. WARNING: Once the parameter has been edited, a complete
uninterrupted opening-closing cycle is required. WARNING: when the
display reads "SET", obstacle detection is not active.
Opening and closing speed of motor(s) during slow-down stage, given as a
percentage of maximum running speed. WARNING: Once the parameter
has been edited, a complete uninterrupted opening-closing cycle is
required. WARNING: When the display reads ""SET"", obstacle detection
is not active.