LIQUID CLEANER SETTING:
use the conical fi lter guard.
(Closed stainless steel jacket for transformation
from dust aspirator to liquid aspirator - OPTIONAL
- Ref.20840)
MEDIUM INOX / OPTIM INOX
FILTER SHAKER OPERATION
FOR OPTIM INOX MODELS:
Invert the position of the flow inverter valve
control lever.
On the INSAC series, when cleaning the fi lter, the dust
from the hopper is released on the bag below.
IMPORTANT
Perform the operations in safe area and with
the container empty if the vacuum cleaner
purchased is ATEX
34
FOR MEDIUM INOX MODELS:
- The filter shaker control rod (B) must be
unhooked
- The flow inverter (A) must be pulled
outwards
A
In order for the filter to be cleaned properly
and correctly it is advisable to continue the
action of the filter shaker for maximum 15
seconds

FILTER REPLACEMENT

FOR OPTIM INOX MODELS:
Access is from underneath the filtering
chamber, removing the filter guard without
removing the motor head.
IMPORTANT
Perform the operations in safe area and with
the container empty if the vacuum cleaner
purchased is ATEX