• Protection functions
Protection functions can extend the life of the air conditioner and provide more comfortable airflow.
>
Delayed start protection for the compressor
The compressor will start to work at least 3 minutes (5 minutes in heating mode) after it stops to maintain the
pressure balance of the refrigeration system.
>
Observations
It will take 1 minute for the compressor to run after the unit is turned on for the first time.
>
Defrost
The outdoor heat exchanger may freeze if the outdoor temperature is low and the humidity is high. In this
case, the automatic defrost will work for 3-10 minutes. the pause indicator will be on and the indoor and
outdoor fans will not work.
>
HEAT overload protection
temperature is too high, the air conditioner enters heating overload protection mode, and the indoor fan speed
should be set to a higher speed automatically. The outdoor fan and compressor can be stopped. When the
indoor pipe temperature drops to a nominal value, the air conditioner exits overload protection mode. The
indoor fan motor returns to its normal state.
>
Residual heat function
The indoor fan keeps running at low speed for 80 seconds when the air conditioner stops in heating mode.
>
Airflow Cooling Test
In the first minutes of heating operation, the PAUSE light will come on; the internal fan does not work and the
flaps cannot be controlled. Approximately 5 minutes later, the air conditioner emits a stream of hot air, the
PAUSE light is off.
>
Avoid freezing
ParIn order to prevent the indoor heat exchanger from freezing during cooling and drying, the compressor or
outdoor fan may stop working; the indoor fan speed will automatically adjust to a higher speed.
>
Auto reset
(optional)
The unit memorizes the operating mode, airflow setting, temperature setting, etc., so that if there is a power
outage when the unit is running, it will automatically return to the same operating condition when it is restored.
energy.
>
Anti drip
During cooling and dehumidifying operations, the louver flaps can automatically change position to prevent
dripping.