VACUUM SYSTEM MOTOR FILTER CLEANING
1.
Drive the machine on a level fl oor.
2.
Turn the ignition key (58) to "0".
3.
Open the cover (20) and check that the recovery tank (19) is empty, otherwise empty it with the drain hose (24).
4.
Close the cover (20).
5.
Carefully lift the tank assembly (44).
6.
Check that the fi lter (37) is clean. If necessary clean it with water and compressed air, then install it.
SOLUTION FILTER CLEANING
1.
Drive the machine on a level fl oor.
2.
Turn the ignition key (58) to "0".
3.
Close the solution valve (A, Fig. 9) under the machine, behind the right rear wheel. The valve (A) is closed when it is in the
position (B) and it is open when it is in the position (C).
4.
Remove the transparent cup (D), recover the gasket (E), then remove the fi lter strainer (F) under the machine, in front of the
right rear wheel. Clean them with water and install them on the support (G).
NOTE
The fi lter strainer (F) must be correctly positioned on the housing of the support (G).
5.
Open the valve (A).
C
A
26
INSTRUCTIONS FOR USE
B
9098827000(2)2010-12
G
F
E
D
Figure 9