Installation Procedure - Toto TSST Manual De Instrucciones Y Del Propietario

Válvula de mexcla termostatica 1/2 (13mm)
Ocultar thumbs Ver también para TSST:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

CAUTION: RISK OF PERSONAL INJURY.
When this valve is installed, it must be calibrated to minimize the risk of
scalding after calibration� The maximum water temperature should never
exceed 120°F (49°C)�
1) Turn off the main water supply�
2) Plumb the valve so that outside of
the finished wall lands between
the max and min indicated on the
plaster guard� (i�e� A=2-1/2" to
3-3/4" [65-95mm]� See where "A"
is located on Illustration 2 below�)
3) Connect the hot water supply to
the left inlet marked "H" and the
cold water supply to the right inlet
marked "C"�
4) Secure the pipes and the valve to
the frame�
5) Remove the plaster guard from
the valve� Use the plaster guard to
trace the cut-out opening�
6) Reattach the plaster guard to the
valve� Do not remove the guard
again until you are ready to install
the trim�
7) Finish the wall�

INSTALLATION PROCEDURE

4
ILLUSTRATION 1
Valve
Plaster
Guard
Hot Water
ILLUSTRATION 2
Plaster Guard
Mixed Water
Out
In
Cold
Water In