4. TECHNICAL SPECIFICATIONS
Inverter power
supply
Inverter output
Mechanical
specifications
Installation
Control and
operating
hydraulic
specifications
Sensors
Functions and
safety devices
Temperatures
Table 1: Technical specifications
Voltage [VAC]
(Tol. +10/-20%)
Phases
Frequency [Hz]
Current [A]
Voltage [VAC]
(Tol. +10/-20%)
Phases
Frequency [Hz]
Current [A rms]
Mechanical power P2
Unit weight [kg]
(only control unit, packaging excluded)
Maximum dimensions [mm]
(WxHxD)
Work position
IP protection rating
Max. ambient temperature [°C]
Differential pressure regulation
range
Type of pressure sensors
Differential pressure sensor full
scale [bar]
Connectivity
Protections
Storage temperature [ºC]
ENGLISH
MCE-150/C
380-480
3
50/60
42,0-33,5
0 - V supply
3
0-200
32,0
20 HP / 15 kW
Housed on pump motor casing
1–95% pressure sensor full scale
Multi inverter connection
Self-protected against current overload
Temperature overload on internal
electronics
Abnormal power supply voltages
Direct short-circuit between the output
phases
6
MCE-110/C
380-480
3
50/60
32,5-26,0
0 - V supply
3
0-200
24,0
15 HP / 11 kW
12,0
343x425x244
55
40
Ratiometric
4/10
-10 ÷ 40

Publicidad

loading

Este manual también es adecuado para: