4. OPERATING INSTRUCTIONS
DC & AC VOLTAGE MEASUREMENT
1. Connect red test lead to "INPUT" jack, Black lead to "COM" jack.
2. Set RANGE switch to desired VOLTAGE range, if the voltage to be
measured is not known beforehand, set switch to the highest range and
reduce it until satisfactory reading is obtained.
3. Connect test leads to device or circuit being measured.
4. Turn on power of the device or circuit being measured voltage value will
appear on Digital Display along with the voltage polarity.
DC & AC CURRENT MEASUREMENT
1. Connect Red lead to "INPUT". Black lead to "COM" (for measurements
between 200 mA and 10 A connect red lead to "10 A" jack with fully
depressed.)
2. Range switch to desired A
range. The default function of the Digital
multimeter is the measurement of DCA.
3. Press "select" button to switch to ACA measurement mode.
4. Open the circuit to be measured, and connect test leads in-series with
the load in with current is to measure.
5. Read current value on the LCD.
RESISTANCE MEASUREMENT
1. Red lead to "INPUT". Black lead to "COM".
2. Range switch to desired
range.
3. If the resistance being measured is connected to a circuit, turn off power
and discharge all capacitors before measurement.
4. Connect test leads to circuit being measured.
5. Read resistance value on Digital Display.