FEATURES AND TECHNICAL
SPECIFICATIONS
ELECTRICAL CONNECTION
Mains power supply
Absorbed power
Fuse
HYDRAULIC CONNECTION
Maximum inlet water temperature
Minimum inlet water temperature
Minimum inlet water flow
Maximum inlet water pressure
Minimum inlet water pressure
PERFORMANCE
Water flow
Maximum pressure
Recoil of cleaner gun
Sound pressure level - Uncertainty (*)
Sound power level
Operator arm vibrations - Uncertainty (*)
WEIGHT AND DIMENSION
Lenght x width x height
Weight
Detergent bottle capacity
(*) Measurements taken in compliance with EN 60335-2-79
All features and technical specifications are only indications. The Manufacturer reserves the right to modify the appliance as it
deems necessary.
USAGE
WARNING: First of all read the General Sec-
tion and then this Specific Manual.
> PUT INTO SERVICE
See fig. A
> STARTING UP
See fig. B
> HIGH PRESSURE LANCE
See fig. D
> DETERGENT SUCTION
See fig. E
20
EFCO IP 1150 S
OLEO-MAC PW 115 C
220 - 240 V - 1 ~ 50/60 Hz
1,75 kW
40 °C - 98 °F
5 °C - 41 °F
900 l/h - 15 l/min - 172 US gph
1 MPa - 10 bar - 145 psi
0,1 MPa - 1 bar - 14,5 psi
360 l/h - 6 l/min - 95 US gph
12,5 MPa - 125 bar - 1813 psi
81 dB(A) - 0,7 dB(A)
96 dB(A)
1,5 m/s² - 0,5 m/ s²
310 x 280 x 650 mm - 12,2 x 11 x 25,6 in
7 kg - 15,4 lb
0,7 l - 0,18 US gal
> HIGH PRESSURE HOSE
See fig. F
> WATER SUPPLY
Water supply collection
WARNING (symbol): machine not suitable
for connection to the potable water mains.
The cleaner can only be connected to the
water mains if the water mains is separated by
a backflow preventer.
Make sure that the hose is at least Ø 13mm-1/2
inch and that it is reinforced.
WARNING: Water that has flown through
backflow preventers is considered to be non-
potable.
16 A
10 N