FEEDER LINES SLOPE
AIR FLOW
WITH AIR FLOW
MAIN DISTRIBUTION AIR LINES
Slope pipe in di rection of air o w.
Water condensate ows along
bottom of pipe to drain legs,
preventing it f rom entering feeder
lines.
.01 MICRON
5 MICRON
FI LTER
FI LTER
SPR AY
GUN
REGUL ATOR
BALL
FI LTER
FOR BEST PERFORMANCE
FI LTER /
the distance between the
MOISTURE
comp ressor and the
TRAP
moistu re trap should be as
long as possible
DRAIN
TYPICAL
VALVE
COMPRESSED AIR
DISTRIBUTION
SYSTEM
RISK OF BURSTING. ALWAYS USE
METAL PIPING AND FITTINGS.
How to Use Your Unit (Fig 3)
How to Stop:
Set the Auto/Off switch to "Off".
Before Starting
WARNING: Do not operate this unit until you read this instruction
AIR FLOW
DRAIN
AIR USAGE
LEGS
LINES
DRAIN
VALVES
FI LTER /
MOISTURE
TRAP
DIR T
LEGS
REGUL ATOR
LUBRIC ATOR
DRAIN
VALVES
AIR
TOOL
FLEXIBLE
COUPLING
GLOBE VALVE /
AIR DISCHARGE
VALVE
AIR
COMPRESSOR
DRAIN
VALVE
manual for safety, operation and maintenance instructions.
Break-in Procedure
NOTICE: Risk of property damage. Serious damage may result if
the following break-in instructions are not closely followed.
This procedure is required before the air compressor is put into
service and when the check valve or a complete compressor pump
has been replaced.
1.
Make sure the Auto/Off switch is in the "Off" position.
2.
Check oil level in pump. See Oil paragraph in the Maintenance
section for instructions.
3.
Recheck all wiring. Make sure wires are secure at all terminals
connections. Make sure all contacts move freely and are not
obstructed.
4.
Open the drain valve (counterclockwise) fully to permit air to
escape and prevent air pressure build up in the air tank during
the break-in period.
5.
Move the Auto/Off switch to "Auto" position. The compressor
will start.
6.
Run the compressor for 30 minutes. Make sure the drain valve
and all air lines are open so there is only a minimal air pressure
build-up in tank.
NOTE: After about 30 minutes, If the unit does not operate
properly, SHUT DOWN IMMEDIATELY, and contact
Product Service.
7.
Check all air line fittings and connections/piping for air leaks
by applying a soap solution. Correct if necessary. NOTE: Minor
leaks can cause the air compressor to overwork, resulting in
premature breakdown or inadequate performance.
8.
Check for excessive vibration. Readjust or shim air compressor
feet, if necessary.