2. INSTALLATION DIAGRAM
The electrical connections at cell-level must not point upwards, to avoid any deposits of water or humidity
on them.
The pH corrector container must be installed at least 2 meters away from any electrical device or any other
chemicals.
Never use hydrochloric acid, its use may lead to irreversible damage to the device and void the warranty. Use
only a pH corrector (acid or basic) recommended by your professional.
22
KEY :
UNO model : white.
DUO model : white + grey.
PRO model : white + grey + black.
I
16
H
19
17
14
4
10
8
4
13
21
1 : Salt / temperature / low water sensor (optional)
2 : Cell
3 : Electronics unit
4 : Filter with ballast
5 : Peristaltic pump
6 : Pool Ground (optional)
7,
8
: Probe holder
9 : Injection connector
10
: ORP probe
11 : pH probe
12,
13
: Bracket
14, 15 : Semi-flexible tubing
ELEMENTS NOT SUPPLIED :
16 : Electrical power supply
17 : pH corrector container
18 : Copper cable
19 : Filter
20 : Ground rod
21 : Heat pump
22 : Filtration pump
3