3.7. Safety
3.7.1. Wintering mode
Wintering mode :
- is activated by default.
- starts automatically as soon as the water temperature drops below 15°C.
When wintering mode is on :
- The message «
- Production is stopped.
- The pH regulation is maintained if it is activated.
To switch off wintering mode : press on OK.
To disable wintering mode : go to the «
3.7.2. Alarms
All alarms are activated by default.
Any alarm that is activated immediately appears on the screen.
To dismiss an alarm : press the OK or
IMMEDIATE
MESSAGE
AUTOMATIC ACTION
DISPLAYED
/ FAULT
Stopping
DETECTED
production
No
Yes
» is displayed.
button (short or long press, depending on the alarm).
CAUSE
Stopping
pH
regulation
pH corrector container
Yes
empty.
No
Cell problem.
», «
» menu.
CHECKS AND REMEDIES
Replace
the
pH
container.
Check that the cell is not scaled.
Inspect and adjust if necessary
the inversion frequency of the
current
supplying
menu).
Check
that
the
connections to the terminals of
the cell are sufficiently tight and
not oxidised.
Check that the cell's power
cable is in good condition.
Check that the cell's power
cable connector is correctly
connected to the electronics
unit.
As a last resort, replace the cell.
OPTION TO
DEACTIVATE
VIA THE
MENU
«
»
corrector
Yes
the
cell
»
electrical
No
14