14. PARAMETERS SETTING
To programme the parameters of the boiler electronic board, proceed as follows:
• Press
together and hold them down for 6 seconds until programme row "P02" appears on the display alternated with
the set value (°C);
• Press
and hold down for 6 seconds until "On" appears on the display. Release the button and "P01" appears on the display;
• Press
to scroll the list of parameters;
• Press
, the value of the selected begins flashing, press
• press
to confirm the value or press
Further information concerning the parameters listed in the following table are supplied together with the required
accessories.
(a)
(b)
ZONE 1 HEATING PARAMETERS (main zone)
P01
700
*Operating mode (0=Frost Protection, 1=Timed, 3=T.comfort)
P02
712
*Reduced ambient temperature
P03
720
*"Kt" curve slope
P04
721
*"Kt" curve drift
P05
726
*"Kt" curve adaptation (0=off)
P06
740
Flow temperature setpoint (minimum value)
P07
741
Flow temperature setpoint (maximum value)
P08
742
*Enable modulating temperature if set = "---"
P09
750
*Room influence ("---" = disabled)
P10
834
*Opening/Closing speed of mix valve
ZONE2 HEATING PARAMETERS (with accessory Expansion Unit)
P11
1000
*Operating mode (0= Frost Protection, 1=Timed, 3=T.comfort)
P12
1010
*Comfort room temperature
P13
1012
*Reduced room temperature
P14
1020
*"Kt" curve slope
P15
1021
*"Kt" curve drift
P16
1026
*"Kt" curve adaptation (0=off)
P17
1040
Flow temperature setpoint (minimum value)
P18
1041
Flow temperature setpoint (maximum value)
P19
1042
*Enable modulating temperature if set = "---" (flow temp. setpoint if P63=0)
P20
1050
*Room influence ("---" = disabled)
P21
1134
*Opening/Closing speed of mix valve
DHW PARAMETERS
Operating mode in DHW (with Remote Control)
P22
1620
0=always enabled, 1=according to hourly heating programme,
2= according to hourly DHW programme.
Anti-legionella function Disabled
P23
1640
0=disabled, 1=periodic (depending on P24)
Periodic anti-legionella function enable (only if P23 =1)
P24
1641
1=daily, 2..6=intervals of 2..6 days, 7=once a week
P25
1663
Circulation temperature setpoint (additional DHW pump)
P26
5470
Preheating time for DHW circuit (1=10' -- 144=1440')
BOILER PARAMETERS
P27
2243
Minimum boiler off time
P28
2217
Frost Protection setpoint
P29
2250
Pump post-circulation time
P30
2441
Max. fan speed (heating)
P31
2455
Minimum boiler off differential
P32
2720
Not used (Do NOT change this parameter)
P33
2721
Not used (Do NOT change this parameter)
SOLAR PLANT PARAMETERS (with accessory Expansion Unit)
P34
3810
Temperature - on differential
P35
3811
Temperature - off differential
P36
3830
Pump start function ("---" = disabled)
P37
3850
Solar panel manifold overheating protection ("---" = disabled)
P38
5050
DHW boiler tank charging temperature max
P39
5051
Maximum temperature of storage tank
to change the value;
to exit without saving.
37
Factory
Minimum Maximum
setting
3
-
0
°C
16
4
1,5
-
0,1
-
0
- 4,5
-
1
0
°C
25
8
°C
80
25
°C
80
25
%
50
1
S
30
30
°C
3
0
°C
20
4
°C
16
4
-
1,5
0,1
-
0
- 4,5
-
1
0
25
°C
8
°C
80
25
80
°C
25
%
50
1
30
s
30
-
2
0
-
0
0
-
7
1
°C
45
8
min
0
0
min
3
0
5
°C
-20
min
3
0
xxx
rpm
0
°C
5
0
0
-
0
-
1
1
°C
8
0
°C
4
0
min
---
5
°C
---
30
°C
65
8
°C
90
8
7221369.01 (1-03/15)
3
35
4
4,5
1
80
80
80
100
873
3
35
35
4
4,5
1
80
80
80
100
873
2
1
7
80
144
20
20
240
8000
20
1
2
40
40
60
350
95
95