H-1075
20" VACUUM SEALER
OPERATING ISSUE
No Green Power Light
No/Poor Vacuum
No Heat/Poor or Weak Seal
No Heat
No Cool
Bag Sticks to Seal Jaw
PAGE 1 OF 6
1-800-295-5510
uline.com
TROUBLESHOOTING
ACTIONS
Check Main Power Switch.
Check fuse.
Is the machine operating?
Has the machine's duty cycle increased?
Check incoming air pressure.
Check bag.
Increase heat time settings.
Check element for hot spots or burn
through. Element should be extended all
the way to the right.
Check element finger nuts.
Check contact surfaces.
Check fuse.
Check bag.
Check the Pressure Bar.
Pour le français, consulter les pages 5-6
RECOMMENDATIONS
Is Power Switch in the ON position?
Replace fuse if necessary.
If yes, green lamp is out on the Main Power Switch. Replace
Power Switch.
Machine has automatically shut down to prevent
overheating. Turn off power and allow machine to cool for
1/2 hour. Turn on Main Power. Call Uline if problem persists.
Air pressure should be set to 75-85 psi.
Make sure bag is flat and crease-free between vac seal
jaws. Use both hands to support bag. Note: Optional support
tray may help when vacuuming larger/bulkier packages.
Replace element. Turn the sealer on again.
Ensure they are tight with no gaps.
Ensure all contact surfaces are clean.
If burnt out, replace fuse.
Increase cool time.
Replace if necessary.
Para español, vea páginas 3-4.
0221 TH-1075