20" VACUUM SEALER
OPERATING ISSUE
No Green Power Light
No/Poor Vacuum
No Heat/Poor or Weak Seal
No Heat
No Cool
Bag Sticks to Seal Jaw
PAGE 1 OF 6
1-800-295-5510
uline.com
TROUBLESHOOTING
ACTIONS
Check Main Power Switch.
Check fuse.
Is the machine operating?
Has the machine's duty cycle increased?
Check incoming air pressure.
Check bag.
Increase heat time settings.
Check element for hot spots or burn
through. Element should be extended all
the way to the right.
Check element finger nuts.
Check contact surfaces.
Check fuse.
Check bag.
Check the Pressure Bar.
Pour le français, consulter les pages 5-6
RECOMMENDATIONS
Is Power Switch in the ON position?
Replace fuse if necessary.
If yes, green lamp is out on the Main Power Switch. Replace
Power Switch.
Machine has automatically shut down to prevent
overheating. Turn off power and allow machine to cool for
1/2 hour. Turn on Main Power. Call Uline if problem persists.
Air pressure should be set to 75-85 psi.
Make sure bag is flat and crease-free between vac seal
jaws. Use both hands to support bag. Note: Optional support
tray may help when vacuuming larger/bulkier packages.
Replace element. Turn the sealer on again.
Ensure they are tight with no gaps.
Ensure all contact surfaces are clean.
If burnt out, replace fuse.
Increase cool time.
Replace if necessary.
Para español, vea páginas 3-4.
0221 TH-1075

Publicidad

loading

Resumen de contenidos para Uline TH-1075

  • Página 1 Has the machine’s duty cycle increased? Machine has automatically shut down to prevent overheating. Turn off power and allow machine to cool for 1/2 hour. Turn on Main Power. Call Uline if problem persists. No/Poor Vacuum Check incoming air pressure.
  • Página 2 Confirm flaps are facing up. Make sure nuts are tight and Element is sparking. replacement. there are no gaps. Jaws do not close Check incoming air pressure. Air pressure should be set to 75-85 psi. 1-800-295-5510 uline.com PAGE 2 OF 6 0221 TH-1075...
  • Página 3 Apague la corriente y permita que incrementado? la máquina se enfríe durante 1/2 hora. Encienda la Corriente Principal. Llame a Uline si el problema persiste. Sellado al vacío inexistente/ Revise la presión de aire de entrada. La presión de aire debería estar configurada a ineficiente 5.2-5.9 kg/cm²...
  • Página 4 Las mordazas no se cierran Revise la presión de aire de entrada. La presión de aire debería estar configurada a 5.2-5.9 kg/cm² (75-85 psi). 800-295-5510 uline.mx PAGE 4 OF 6 0221 TH-1075...
  • Página 5 Le cycle de fonctionnement de l'appareil L'appareil s'est éteint automatiquement pour éviter une a-t-il augmenté? surchauffe. Éteignez l'appareil et laissez-le refroidir pendant 1/2 heure. Allumer l'appareil. Communiquez avec Uline si le problème persiste. Aucune ou faible pression Vérifiez la pression d'air entrant.
  • Página 6 Assurez-vous que les écrous sont serrés et il n'y a pas produit des étincelles. chauffant. d'ouverture. Les mâchoires ne ferment pas Vérifiez la pression d'air entrant. La pression d'air doit être définie entre 5,2 à 5,9 kg/cm² (75 et 85 lb/po²). 1-800-295-5510 uline.com PAGE 6 OF 6 0221 TH-1075...