OPERATING ISSUE
Gaps/Creases in Seal
Nozzle does not retract or
extends too slow/fast
The Pressure Bar does not
close. One side sticks open.
Premature element burn out.
Element is sparking.
Jaws do not close
PAGE 2 OF 6
TROUBLESHOOTING CONTINUED
ACTIONS
Check bag.
Check element and Teflon
®
hot spots, burns or creases.
Check incoming air pressure.
Adjust Nozzle Extend Flow Control.
Realign Pressure Bar pistons.
Check procedure for proper element
replacement.
Check incoming air pressure.
1-800-295-5510
RECOMMENDATIONS
Ensure bag is flat when vac jaw closes.
for bumps,
Increase heat and cool times. Replace element and Teflon
as necessary.
Air pressure should be set at 75-85 psi.
Reduce/increase opening in Nozzle Extend Flow Control to
slow down/speed up nozzle extend.
To realign, disconnect air pressure, close jaw by hand,
loosen and retighten Pressure Bar piston nuts.
Confirm flaps are facing up. Make sure nuts are tight and
there are no gaps.
Air pressure should be set to 75-85 psi.