F1.7 Load-point Calibration
[LOAd] Loading weights
Load weights on the weighing platform to ensure that 10% of full-scale value ≤ weight of weights ≤ full-scale value, and then press
the
key to start the next step.
[000000] Entering the same weight value as that of the loaded weights.
Entering the same weight value as that of the loaded weights, please press the
meter will display [ ]. After that, the displayed digits will reduce slowly until the meter displays [ ]. In the end it will display [ ] for one
second, which indicates the end of null-point calibration.
F1.8 Automatic Null Tracking
Selectable parameters: OFF, 1 d, 2 d, 3 d (default value)
F1.9 Automatic Reset Range at Startup
Selectable parameters: OFF, 2 %, 10 %, 20 % (default value)
F1.10 Button Reset Range
Selectable parameters: OFF, 2 %, 10 % (default value), 20 %
F1.11 Digital Filter
Selectable parameters: 0 ---- Mild Filtering
F1.12 Steady Range
Selectable parameters: 1 d, 2 d, 3 d (default value)
F1.13 Overload Display Range
Selectable Parameters: 9d, 5% (default value), 10%, 20%
F1.14 F1 Menu Protection
Selectable Parameters: 0 ---- Enter F1 menu by keyboard operation
F1.15 Restoring Factory Default
Set the parameters within F1~F4 as the defaults, which can't impact the parameters of standard scale.
F2 APPLICATION FUNCTION SETTING
F2.1 Function Selection
Selectable Parameters: 0 ---- Close the application functions (default value)
12
1 ---- Moderate Filtering (default value)
2 ---- Severe Filtering
1 ---- Enter F1 menu by pressing the calibration button
1 ---- Weight keeping function
REPORT
---------------------------
Gross
0.200 Kg
Tare
0.000 Kg
Net
0.200 Kg
REPORT
---------------------------
Gross
0.200 Kg
Tare
0.000 Kg
Net
0.200 Kg
REPORT
---------------------------
Gross
25.000 Kg
Status
Hold
USER'S MANUAL ARX
key after the scale becomes stable, and the
REPORT
---------------------------
Net
25.000 Kg
Status
EN
Hold