Baxtran ARX Manual De Usuario página 15

Transpaleta pesadora
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PERCENTAGE DISPLAY F2.1 = 2
Display specification
Display [Pr 20.5], representing 20.5 %.
Pr = current actual weight / range ×100%.
Press
to display switch in percentage and weight.
CHECK WEIGHT AND SELECTION SCALE FUNCTION F2.1 = 3
Function description
Set parameters such as F2.2 = A, F2.3 = B, F2.4 = C and F2.5 = D.
When display weight is X.
If X ≤ A, do not conduct check weight and selection.
If X < (B – D), it lacks of weight, and the display flickers.
If (B – D) ≤ X ≤ (B – C), it is qualified and the display has normal display
If X > (B – C), it is overweight and the display flickers.
Acquisition of target value
Press
long until the display shows [TARGET], and then press
If F2.6 = 0, press
, the instrument will take the weight on current scale as the new target value and quit the setting interface.
If F2.6 = 1, the display shows [000000], to request manual change of target value. After change, press
and quit setting interface.
FUNCTION OF ACCUMULATION SCALE F2.1 = 4
Operation method
In normal weighing state, when the scale is in , add weight to the scale and press
[Add--] progress bar, it indicates that the current display weight is included accumulated value, and then it returns to normal weighing
state. If the display shows [--no--] for a second, and returns to the normal weighing state, it indicates operation is invalid. Reason:
1. Between two accumulation operations, the scale must have back-to- process, otherwise, accumulation is refused. 2. Accumulation
operation is effective only when display weight≥F2.2 is set. 3. The scale is in dynamic state.
Adjustment, clearing and printing of accumulated value
In normal weighing state, press
then the display shows current total accumulated value [A 9.500] and flickers. To clear accumulated value, press [Pr 20.5], to make
flicker weight be 0. Press
Attention: set whether to be over detailed data or accumulated data in F4.6.
FUNCTION OF COUNTING SCALE F2.1 = 5
Instrument display
[c 128], showing current quantity.
Sampling method
1. Check whether the scale is in , if not, press
2. Place materials counted on the scale.
3. Press
long until the display shows [SAMPLE], and then press
quantity counted just now, and press
If F2.6 = 1, the display shows [000000], input sample weight. Press
setting interface.
4. In this function, press
on operation panel for more than 2 seconds, the display will show [Zero] for a second, and
to print accumulated data. Press
for setting.
for confirmation. The instrument saves sampling data and quits the sampling interface.
to display switch between quantity and weight.
to show current target value and flicker.
on operation panel, if the display shows
to quit the interface.
. If F2.6 = 0, the display shows [PC5 00]. Input the
, the instrument saves setting data and quits sampling
USER'S MANUAL ARX
to save setting data
EN
15

Publicidad

Tabla de contenido
loading

Tabla de contenido