LOCATION AND INSTALLATION REQUIREMENTS
Mechanical issues
• According to safety regulations, the lowest point of the fan blade must be at least 2.3m (7
feet) from the floor.
• Please, make sure the chosen location will not allow the rotating fan blades to come into
contact with any objects.
• Ensure ceiling joists are sound and of adequate size and strength to support the weight
of the fan.
• To reduce the risk of fire, electrical shock or personal injury, ensure that the fan mounting
bracket is supported directly from the building structure. DO NOT mount to an outlet box.
• The mounting bracket must be firmly screwed to a load bearing structure, e.g. a concrete
ceiling, steel structure or timber frame. If a timber frame is added, it must be securely
nailed or screwed between two beams.
• To reduce risk of personal injury and property damage, do not bend or damage the down-
rod or the fan blades when handling or installing them. If you notice any product imper-
fections, please contact our after-sales service before proceeding to install the fan.
• Make sure the ceiling fan is securely fastened to the ceiling. All set screws must be
checked and re-tightened where necessary before fan operation.
Electrical issues
• Always turn the power off before servicing the ceiling fan, turn off the circuit breaker that
feeds the power to the light. To avoid possible electric shock, make sure electricity is turned
off at the fuse box or circuit breaker panel before wiring.
• The fan, mounting bracket and light kit must be earthed. Ensure all spliced connections are
adequately insulated.
Remote control connection
• Make the connection between the receiver cables and the fan motor cables following the
color indications. Make sure the connection is tight.
Ground
wire
L
N
Hanging the fan
• Hang the fan on the ceiling mount. Bring the suspension axle closer to the bracket and let
the motor assembly rest on the roof bracket. Insert the remote control receiver into the left
space when installing the ceiling mount, between the ceiling and the suspension bar. So that
the connection cables are outside the metal plate to connect the cables.
• Pass the receiver first, letting the cables protrude through the sides of the bracket, as indi-
cated in the drawings.
E NGL I SH
8
Light L
Remote
Input L
Fan L
control
receiver
Input N
Neutral N
Ground wire
Light L
Motor L
Neutral N