Descargar Imprimir esta página

Louisiana Grills LG700SL Manual Del Propietário página 17

Publicidad

Idiomas disponibles

Idiomas disponibles

Er1 Error Code
Grill probe is not making a
connection
ErH Error Code
The unit has overheated,
possibly due to grease fire
or excess fuel
FAN Icon Is Blinking
Fan is not making a
connection
IGNITOR Icon Is Blinking
Igniter is not making a
connection
AUGER Icon Is Blinking
Auger motor is not making a
connection
PELLET Icon Is Blinking
Lack of fuel, poor fuel
quality, obstruction in feed
system
Check for damage to the grill probe. Follow care and maintenance instructions if
dirty. If all appears in working order, check the connection to the digital Control
Board. Unplug unit from power source. Remove hopper access panel (see electric
wire diagram for diagram). Locate the white wires of the grill probe. Disconnect the
spade connectors, then reconnect until it clicks. Replace the hopper access panel.
Unplug unit from power source and allow to cool. Follow care and maintenance
instructions. Remove ashes and unburnt pellets from burn grate and bottom of
the grill. Check burn grate for proper positioning. Check proper positioning of
cooking components. After maintenance, plug unit into power source and press
and hold the Power button for three seconds to turn the unit on. If error code is still
displayed, contact Customer Care.
Unplug unit from power source. Remove hopper access panel (see electric wire
diagram for diagram). Locate the blue and white wires of the fan. Check fan blades
for damage. Follow care and maintenance instructions if dirty. Disconnect the
spade connectors, then reconnect until it clicks. Replace the hopper access panel.
If error code is still displayed, contact Customer Care.
Unplug unit from power source. Remove hopper access panel (see electric wire
diagram for diagram). Locate the red and white wires of the igniter. Disconnect the
spade connectors, then reconnect until it clicks. Replace the hopper access panel.
If error code is still displayed, contact Customer Care.
Unplug unit from power source. Remove hopper access panel (see electric wire
diagram for diagram). Locate the yellow and white wires of the auger motor.
Check auger motor and bracket for damage. Disconnect the spade connectors,
then reconnect until it clicks. Replace the hopper access panel. If error code is still
displayed, contact Customer Care.
Check hopper to check that fuel level is sufficient, and replenish if low. Should
the quality of wood pellets be poor, or the length of the pellets too long, this may
cause an obstruction in the feed system. Remove pellets and follow care and
maintenance instructions.
www.louisiana-grills.com