INSTALLATION CONTINUED . . .
8. Connecting the Storage Tank to the System
When tank is full, it weighs approximately 19.50 lbs. (8.8 kg.) Provide
CAUTION
ample support under the tank.
(A) To prevent leaks, apply 3 or more wraps of plumber tape to threads on tank.
Thread the tank valve onto the top of the tank opening. Turn tank so handle is
in line with tubing.
The tank/valve connection will leak if not properly sealed. Plumber
CAUTION
tape will normally seal the threaded connection.
(B) Locate the 3/8" blue tubing. Place a mark on the tubing 5/8" from one end.
Moisten the marked end of the tubing with water and insert with a twisting
motion into the port of the tank valve until the 5/8" mark is flush with the
quick connect fitting. Then locate the tank near the system's installation
area.
(C) Cut the tubing to correct length. Install free end of tubing into white
quick-connect fitting on the system. Ensure the tubing does not kink. Retain
remaining blue tubing for use in connecting system to water supply adapter.
Some installation sites may require additional tubing not provided in kit.
(D) Place entire system over mounting screws on wall and slide down.
Make certain system is firmly attached to wall to prevent it from falling
CAUTION
and possibly becoming damaged.
NOTE: Use caution not to bend or pinch the tubing behind the system while
attaching to mounting screws.
9. Connecting the System to the Water Supply Adapter
(A) Locate remaining length of 3/8" plastic blue tubing.
(B) Place a mark on the tubing 5/8" from the end. Moisten the end of the tubing
with water and insert with a twisting motion push into white quick connect
fitting on the left side of system. Depending on the installation, the system
may need to be removed from the mounting surface to access the left side of
the system.
(C) Cut the tube to a length that will allow connection to the Water Supply
Adapter. Ensure the tubing does not kink. Place a mark on the tubing
5/8" from the end. Moisten the end of the tubing with water and insert with a
twisting motion push into quick connect fitting on the Water Supply Adapter.
10. Faucet Operation
(A) For controlled water flow, push the handle down.
(B) For constant water flow, lift the faucet handle to lock it in the open position.
All manuals and user guides at all-guidesbox.com
FRESHPOINT GRO-350BP Installation and Operation Manual • 9
8
3/8" Tube
Apply
plumber
5/8"
tape
B
9
RO DRAIN LINE
(3/8" RED)
RO INLET LINE (3/8" WHITE)
RO LINE TO TANK
(3/8" BLUE)
10
A
A
FAUCET DRAIN LINE (1/4" RED)
RO OUTLET LINE (3/8" BLUE)
Push Down
B
Push Up

Publicidad