Safety Notes; Installation Instructions; Technical Data; Symbol Description - Hansgrohe Marin2Set Eco 27324000 Modo De Empleo/Instrucciones De Montaje

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 6

Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal pres-
sures.
Children as well as adults with physical, mental and/
or sensoric impairments must not use this product
without proper supervision. Persons under the influ-
ence of alcohol or drugs are prohibited from using
this product.
For safety reasons, it is forbidden to remove the
EcoSmart (flow limiter) installed in the shower
#28561000.
Shower hoses are only suitable for a connection
from the shower to the fitting. Never fit a shut-off
device between the fitting and the hose.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The plumbing codes applicable in the respective
countries must be observed.
• During installation of the product by qualified trained
personnel, make sure that the entire fastening surface
is even and smooth (no protruding seams or tile
offset), that the finish of the wall is suitable to apply the
product and has no weak points.
• The filter insert must be use to protect the shower
against incoming dirt by pipework. Incoming dirt leads
to defects or/and can damage parts of the shower;
such caused faults voids all liability and guarantee
claims.
• Optimal functioning is only guaranteed with the com-
bination of Hansgrohe hand showers and Hansgrohe
shower hoses.
4
English

Technical Data

This mixer series-produced with EcoSmart
(flow limiter)
Operating pressure:
Recommended operating pressure:
Hot water temperature:
Thermal disinfection:
The product is exclusively designed for drinking water!
Assembly see page 33

Symbol description

Do not use silicone containing acetic acid!
Dimensions (see page 31)
Flow diagram (see page 32)
Operation (see page 36)
Hansgrohe recommends not to use as drink-
ing water the first half liter of water drawn
in the morning or after a prolonged period
of non-use.
Cleaning (see page 38)
Spare parts (see page 37)
Test certificate (see page 40)
®
max. 0,6 MPa
0,1 - 0,4 MPa
max. 60°C
max. 70°C / 4 min