Installation variants
 A
• Variant (a): Submerged pump installation
– The pump is positioned in the pond or basin.
– Water flow via the filter cage.
• Variant (b): Dry pump installation
– The pump is installed without the filter cage outside of the pond or basin but lower than the
water level.
– Water flow via a satellite filter or skimmer.
Installation and connection
The pump can be installed submerged (in water) or dry (outside the water).
The use of the pump is only permitted with observance of the specified water quality.
WARNING
Severe injuries or death due to operation of this unit in a swimming pond. Defective electrical
components will electrify the water with dangerous electrical voltage.
Never operate the unit in a swimming pond.
NOTE
If the pump is used for conveying excessively soiled water, the impeller unit will be subject to in-
creased wear and will require earlier replacement.
Thoroughly clean the pond or pool before installing the pump.
Install the pump at a raised level above the bottom. This reduces intake of muddy water.
Avoid direct sunlight on unit components that are not submerged, as they may overheat. If
necessary, use a protective cover.
Submerged installation of the pump
Connecting
 B
Do not plug the power plug into the socket yet!
Installation
 C
• Place the pump horizontally on a stable, mud-free surface.
• Ensure secure and stable positioning of the pump.
• Only operate the pump when it is fully submerged.