Operating instructions /
Description of function
The control unit allows a variety of operating modes:
Dead man OPEN / dead man CLOSE
Pressing button
and keeping it pressed causes the
door to open until the OPEN end-of-travel position is
reached. Releasing the button causes the door to
stop. The door is closed by dead man's control, i.e.
pressing button
and keeping it pressed, until the
door reaches its CLOSE end-of-travel position. If the
button
is released during closing, the door stops
instantly.
Impulse OPEN / dead man CLOSE
By briefly pressing the button
impulse from an external impulse generator, the door
starts to open until reaching the OPEN end-of-travel
position or the door can be stopped beforehand by
pressing button . If button
is pressed again, the
door continues to open. The door is closed by dead
man's control, i.e. pressing button
pressed, until the door reaches its CLOSE end-of-
travel position. If the button
closing, the door stops instantly.
Impulse OPEN / impulse CLOSE
By briefly pressing button
or generating an impulse
from an external impulse generator the door starts to
open until reaching the OPEN end-of-travel position,
or the door can be stopped beforehand by pressing
button . By briefly pressing button
closing until reaching the CLOSE end-of-travel
position.
This operating mode demands that a safety edge
(menu 35) be installed. If the safety edge is triggered
during closing, the door stops and changes direction.
If the safety edge is triggered during opening, this has
no effect. In the case of a defect, the door can be
closed using dead man's control.
AR-mode / automatic closing
By briefly pressing button
or generating an impulse
from an external impulse generator, the door starts
opening until reaching the OPEN end-of-travel
position. Or the door was stopped prematurely using
button . Once the set hold-open time has elapsed,
there follows an early warning phase of 10 seconds,
after which time the door automatically closes.
If button
is pressed when the door is in the open
position or while it is closing, the door is immobilized
until a new impulse
or is generated.
AR-mode with shortened response time via
photocell
Function as described above, but an interruption of
the photocell causes the set hold-open time to be
terminated and the early warning phase to begin.
After the early warning phase has expired, the door
automatically closes.
Half-opening of the door
Pressing the ½ button initiates the set half-opening of
the door (menu 32).This function is not available in
the dead man OPEN / dead man CLOSE operating
mode.
Lighting and / or early warning light
The control unit has two relay outputs allowing the
switching of lighting or the early warning light (menu
45 and 46).
Key switch function (optional)
The control unit has an input for a key switch. This
allows you to activate the following functions (menu
50):
0
Key switch without function (factory
default)
1
2
3
4
5
6
External command units / impulse generators
The door can be opened and closed via external
command units/impulse generators.
Radio hand transmitter (optional)
or generating an
Button: Start
First impulse:
The operator starts up and causes the door to travel
to the set OPEN or CLOSE travel limits.
Impulse generated during travel:
and keeping it
Door stops.
A new impulse is generated:
is released during
Door continues to travel but in the opposite direction.
½ button for half-opening:
Function as with the START button, but the door
travels to the set half-open position only.
Button: Light
the door starts
The light function involves a continuous light that can
be switched on/off independent of the door action.
Control panel on the control unit is
blocked.
All external control elements are
blocked.
Control panel on the control unit and all
external control elements are blocked.
For 10 secs. the control panel on the
control unit and all the external control
elements are active.
Switching of operating mode to impulse
OPEN / dead man CLOSE.
Half-opening function is blocked.
Maintenance / Checks
For your own safety, we recommend
that prior to initial operation and
whenever required - however at least
once a year, you have the door system
tested by a specialist company.
Service display
If the control unit establishes the need for testing /
inspection, "service" shows up in the display. Contact
a specialist company.