15
Menu stage 3: Direction of travel
In menu stage 3 the direction of travel can be
changed, e.g. LH/RH installation.
Hold button
pressed for 3 seconds. A "3" is
displayed.
After approx. 2 seconds, a "0" flashes for
installation on the RH side of the door (factory
setting) 15a.
If the operator is installed on the LH side of the
door, press button
and a "1" flashes 15b.
16
Menu stage 4: Positioning
This menu stage serves to position the limit switch
actuator.
Press button
- a "4" is displayed 16a. As soon
as the "4" starts flashing, you can press button
open the door, and button
to close the door 16b.
Important: If on pressing the buttons, the door
travels in the opposite direction, the direction must
then be changed in menu stage 3 (see
stage 3).
17
Limit switch actuator
Setting the OPEN position 17c:
Now actuate the door to travel to the desired
OPEN position by pressing button
switch actuator on the top part of the track behind
the motor head 17a.
Push the limit switch actuator into the guide of the
motor head 17b.
To test, press button
to cause the operator to
travel approx. 10 cm in the CLOSE direction and
then press button
to cause the door to open
again. On reaching the limit switch actuator, the
operator cuts out.
If the cut-out position is correct, carefully tighten
the screw on the limit switch actuator - otherwise
re-adjust the limit switch actuator and repeat the
test.
Setting the CLOSE position 17d:
Now allow the door to travel to the desired CLOSE
position by pressing button
.
Set the limit switch actuator on the top part of the
track in front of the motor head 17a.
Push the limit switch actuator into the guide of the
motor head 17b.
To test, press button
to cause the operator to
travel approx. 10 cm in the OPEN direction and
then press button
to cause the door to close
again. On reaching the limit switch actuator, the
operator cuts out.
If the cut-out position is correct, carefully tighten
the screw on the limit switch actuator - otherwise
re-adjust the limit switch actuator and repeat the
test.
18
Maiden operations
Quit the programming menu - press button
repeatedly until a "0" appears 18a. Fully open the
door. The operator needs to perform a maiden run
on both the closing and opening cycles in order to
register the distances covered by the door as well
as the forces required 'by it'. To start, press in each
instance button
18b.
Caution: Maiden operations are not force-
monitored. The travel cycles must not be
interrupted. The maiden operations are completed
when the "0" disappears.
19
Menu stage 5: Force limit for the opening
cycle
Again in the setting menu, press button
For 3 seconds until a "3" appears. Then press
Retain these installation, operating and maintenance instructions for the full duration of the operator's service life!
button
twice until a "5" appears.
After approx. 2 seconds the display flashes
showing the set value of the power limit for the
opening cycle.
The force limit setting can be increased or
decreased via buttons
is "4"!
After selecting the setting, press button
A "6" is displayed.
20
Menu stage 6: Force limit for the closing
cycle
After approx. 2 seconds the display flashes
showing the set value of the force limit for the
closing cycle.
The force limit setting can be increased or
to
decreased via the
After setting the value, press button
displayed.
Finally, check the force settings and if necessary
15
menu
repeat the setting procedure.The force at the main
closing edge may not exceed the values stipulated
in DIN EN 12453. Depending on the use of the
door and on the basis of national regulations,
further reaching protective measures may be
necessary.
. Set the limit
This applies, for example, to collective garages,
underground garages etc.
Caution! If the force is set too high,this can result
in injury to persons and damage to property. The
factory setting is "4"!
21
Checking the force limit device
- Place an obstruction (e. g. operator's cardboard
box) underneath the door's closing edge.
- Start the door from the OPEN end-of-travel
position.
- The door travels towards the obstruction, stops,
then travels back to the top end-of-travel
position.
- The point display (a) must switch off for approx.
1 second. The operator then functions as normal
again.
If the door springs were altered, the maiden
operation to learn the force limit must then be
repeated:
Proceed to menu stage 5 and keep button
pressed for 3 seconds. A "0" is displayed. Now
carry out maiden operations to learn the force limit,
as explained under point 18.
22
Menu stage 1: Programming the start
function for the hand transmitter
Briefly press button
As soon as the display starts to flash, keep the
button of the hand transmitter, with which you
would later like to start the operator, pressed for
approx. 1 second.
As soon as the code has been read in, the red
point display (a) flashes five times to acknowledge.
Further hand transmitters (up to a maximum of 10
button codes) can be programmed.
23
Menu stage 3: Programming the light
function for the hand transmitter
Press button
Note: If no 4-minute light is to be programmed,
press button
A "0" is displayed indicating that the programming
is completed.
.
Press the second button on the hand transmitter
with which the 4-minute light is to be switched on.
and
. The factory setting
.
and
buttons.
. A "0" is
. A "1" is displayed.
. A "2" is displayed.
once again.
As soon as the code has been read in, the red
point display (a) flashes five times by way of
acknowledgement.
After the code has been learned, briefly press
button
. A"0" is displayed. The menu is
completed.
Deleting all the hand transmitters programmed
for the operator:
Plug in the operator's mains plug and in doing so
keep button
pressed.

Special settings

Menu stage 7: Light phases
Keep butto
pressed for 3 seconds.A "3" is
displayed.
Press button
repeatedly until menu stage 6 is
displayed.
Keep button
pressed for another 3 seconds
until a "7" is displayed.
Menu
Light phase
Warning
Value
0
60 s
1
90 s
2
120 s
3
240 s
4
0 s
5
90 s
6
240 s
7
0 s
10 s
8
90 s
10 s
9
240 s
10 s
The setting can be altered using the
buttons. If the warning phase is set, the light
flashes before the door starts to move and during
the actual travel cycle. The factory setting is "1".
Press button
to quit the menu.
24
Internal impulse generators
The cover on the control unit is used as an impulse
generator for opening and closing inside the
garage. Briefly press the cover and the operator
starts up 24.
25
Disengagement
The operator is equipped with a quick release. By
pulling the pull cord with knob, the operator can be
permanently disengaged from the door 25a.
The motor head can be re-engaged at any point
between the two limit switch actuators. To lock in
place, press down the lever 25b.
26
Installation on the LH side of the door
If favoured by the structural conditions on site, the
operator can also be installed on the left-hand side
26a. Loosen bolts on motor head with wrenches
(SW 10 and 17 mm) 26b and screw them back on
on the other side 26c.
27
Installation: Low-mounted control unit
If the control unit cannot be positioned directly
underneath the track 27a, the coiled cable can
then be routed to the motor head using the
supplied second cable clamp and the perforated
strip 27b. The extendible part of the coiled cable
may be stretched by a maximum of factor 3 and
the permanently laid part by a maximum of factor
7.
If the coiled cable is not long enough, the
extension set (accessory) should be used.