Trouble-shooting
Important note: When working on the operator, always pull out the mains plug beforehand!
Malfunction
Door does not open / close fully.
After closing, door opens again to produce a
slight gap.
Operator does not move although the motor is
running.
Door does not respond to impulse from hand
transmitter - but does respond to push-button
or other impulse generators.
Door does not respond to impulse from hand
transmitter nor to other impulse generators.
Insufficient range of the hand transmitter.

Diagnostic display

During operation, the display provides diagnostic information on any possible faults and/or malfunctions
Number
State
0
Operator starts up and "0" goes out.
1
Door neither opens nor closes.
2
Door no longer closes.
3
Motor does not rotate.
4
Permanent impulse signal at the start input.
5
Operator does not reach the end-of-travel position.
0
0" stays displayed during the next opening and closing
cycle and then goes out.
"0" continues to be displayed.
Type designation:
______________
Production Number:______________
(see type plate)
Date of purchase:______________
Date when firstAddress / stamp of company
put into service:______________carrying out the order: _________________________
Retain these installation, operating and maintenance instructions for the full duration of the operator's service life!
Possibles causes
Door mechanics have changed.
Closing / opening force has been set too weak.
End-of-travel position is incorrectly set.
Door blocks just before reaching the closed
position.
End-of-travel position is incorrectly set.
Operator ist not engaged.
Battery in the hand transmitter is flat.
Aerial not plugged in or not aligned.
No hand transmitter has been programmed.
See diagnostic display.
Battery in the hand transmitter is flat.
Aerial not plugged / aligned.
On-site screening of the receiving signal.
Diagnosis / Remedy
Operator receives a start impulse at the START input or via a receiver.
Normal operation
STOP A connection is interrupted.
External safety device has been activated (e.g. wicket pass door).
STOP B connection is interrupted.
External safety device has been activated (e.g. photocell).
Call in a specialist.
Door no longer accepts a start impulse.
External impulse generator emits a permanent impulse signal (e.g. button is
jammed).
Operator is disengaged, re-engage 25b.
Limit switch is not actuated. Re-set the end-of-travel position
The operator is performing a maiden operation to learn the force limit.
Caution: These cycles are not force-monitored!
Limit switch is not actuated. Re-set the end-of-travel position
Warranty Document
Remedy
Have the door checked.
Set the force (menu stages 5 and 6).
Re-set end-of-travel position
17
Remove the obstruction.
Re-set the CLOSE end-of-travel position
Re-engage operator 25b.
Replace battery in the hand transmitter.
Plug in aerial / align.
Programme hand transmitter
22
See diagnostic display.
Replace battery in the hand transmitter.
Plug in / align aerial.
Connect external aerial (accessory).
GB
.
17
.
(menu stage 1)
17
.
17
.
Subject to changes