Industry Canada
Certificación PROFINET con
Ethernet APL
Normas y directrices
externas
Endress+Hauser
The devices are compliant with the FCC Code of Federal Regulations, CFR 47, Part 15, Sections
15.205, 15.207, 15.209.
In addition, the devices with following listed antennas are compliant with Section 15.256:
• Encapsulated antenna, PVDF, 40 mm (1,5 in)
• Drip-off antenna 50 mm (2 in)
• Integrated antenna, PEEK, 20 mm (0,75 in)
• Integrated antenna, PEEK, 40 mm (1,5 in)
For these LPR (Level Probe Radar) applications the devices must be professionally installed in a
downward operating position. In addition, the devices are not allowed to be mounted in a zone
of 4 km (2,49 mi) around RAS stations and within a radius of 40 km (24,86 mi) around RAS
stations the maxium operation height of devices is 15 m (49 ft) above ground.
Canada CNR-Gen Section 7.1.3
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to
the following two conditions: (1) This device may not interference, and (2) this device must accept
any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d' I ndustrie Canada applicables aux appareils radio exempts
de licence. L' e xploitation est autorisée aux deux conditions suivantes : (1) l' a ppareil ne doit pas
produire de brouillage, et (2) l' u tilisateur de l' a ppareil doit accepter tout brouillage radioélectrique
subi, même si le brouillage est susceptible d' e n compromettre le fonctionnement.
[Any] changes or modifications not expressly approved by the party responsible for compliance could
void the user' s authority to operate the equipment.
• The installation of the LPR/TLPR device shall be done by trained installers, in strict compliance
with the manufacturer's instructions.
• The use of this device is on a "no-interference, no-protection" basis. That is, the user shall accept
operations of high-powered radar in the same frequency band which may interfere with or
damage this device. However, devices found to interfere with primary licensing operations will be
required to be removed at the user's expense.
• This device shall be installed and operated in a completely enclosed container to prevent RF
emissions, which can otherwise interfere with aeronautical navigation.
• The installer/user of this device shall ensure that it is at least 10 km from the Dominion
Astrophysical Radio Observatory (DRAO) near Penticton, British Columbia. The coordinates of the
DRAO are latitude 49°19ʹ15ʹʹ N and longitude 119°37ʹ12ʹʹ W. For devices not meeting this 10 km
separation (e.g., those in the Okanagan Valley, British Columbia,) the installer/user must
coordinate with, and obtain the written concurrence of, the Director of the DRAO before the
equipment can be installed or operated. The Director of the DRAO may be contacted at
250-497-2300 (tel.) or 250-497-2355 (fax). (Alternatively, the Manager, Regulatory Standards
Industry Canada, may be contacted.)
• The Model FMR60B fulfills the requirements for use as LPR (Level Probe Radar).
• The Model FMR60BT is a submodel of the FMR60B that fullfills the requirements for use as
TLPR (Tank Level Probe Radar).
Interfaz PROFINET con Ethernet APL
El equipo está certificado y registrado por la PNO (PROFIBUS Nutzerorganisation e.V. / la
organización de usuarios de PROFIBUS). El sistema de medición cumple todos los requisitos de las
especificaciones siguientes:
• Certificado conforme a:
• Especificaciones para la verificación de los equipos PROFINET
• Nivel de seguridad de PROFINET: Clase Netload
• El equipo también se puede hacer funcionar con equipos certificados de otros fabricantes
(interoperabilidad)
• EN 60529
Grados de protección proporcionados por las envolventes (código IP)
• EN 61010-1
Requisitos de seguridad para equipos eléctricos de medición, control y uso en laboratorio
• IEC/EN 61326
Emisiones conformes a requisitos A de Clase A; compatibilidad electromagnética (requisitos de
EMC)