Descargar Imprimir esta página

Dometic 10 Serie Instrucciones De Montaje página 18

Ocultar thumbs Ver también para 10 Serie:

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 57
Installing the refrigerator
1. Determine the required cross section of the cable in relation to the cable length
according to fig. 6, page 6.
2. Connect the cables to the AMP connector of the refrigerator (fig. 7, page 7).
3. Connect the other ends of the cables to the
A
NOTICE! Damage hazard
• Make sure the polarity is correct.
• Fit the positive (+) cable with a 10 A fuse.
– As directly as possible
– rd (red): With a fuse protection (10 A) fitted to the positive (+) pole
– bk (black): To the negative (–) pole
4.5
Securing the refrigerator
A
NOTICE! Damage hazard
Only screw through the bushings provided, otherwise foamed compo-
nents, such as cables, can be damaged.
I
NOTE
• Attach the side walls or the attached strips so that the screws are
tight, even under increased loads (while driving).
• The refrigerator is designed to provide a regulated air flow. The man-
ufacturer does not recommend to leave additional space between
the refrigerator and the recess walls.
1. Move the refrigerator into its final location with the front flange sitting tight
against the recess front.
2. Fasten the screws (fig. 8, page 7) through the plastic bushings in the sides of
the refrigerator, and further into the wall.
3. Put the caps onto the screw heads.
4.6
Installing the control panel
A
NOTICE! Damage hazard
Lay the connection cables in such a way that they are not damaged (e.g.
by sharp edges or strong bends).
RC10.4P.100
➤ Install the control panel as shown (fig. 0, page 8).
18
RC(S)(L)(D)10-Series
power supply:
12 Vg
EN

Publicidad

loading