Emptying the container
CAUTION!
Before proceeding with these operations, turn off the
machine and remove the plug from the power socket.
Check the machine filtration class.
Before emptying the container it is advisable to clean the filter
(see "Cleaning the primary filter" paragraph).
Figure 1
Release the dust container (2) with the lever (3), then
remove and empty it.
Clean the machine as described in the "Maintenance,
cleaning and decontamination" paragraph.
Wash the container with clean water if aggressive
substances have been vacuumed.
Make sure the gasket is in perfect condition and correctly
positioned.
Place the container back in position and secure it again.
[ NOTE ]
After the cleaning session, leave the machine running for at
least 60 seconds before turning it off.
Avoid switching on/off too frequently.
Emptying of the liquid container
CAUTION!
Before proceeding with these operations, turn off the
machine and remove the plug from the power socket.
Check the machine filtration class.
Before emptying the container it is advisable to clean the filter
(see "Cleaning the primary filter" paragraph).
Figure 1
Release the container (2) with the lever (3) and remove it,
then remove the liquid stop device and empty it.
Clean the machine as described in the "Maintenance,
cleaning and decontamination" paragraph.
Wash the container with clean water if aggressive
substances have been vacuumed.
Make sure the gasket is in perfect condition and correctly
positioned.
Place the container back in position and secure it again.
[ NOTE ]
After the cleaning session, leave the machine running for at
least 60 seconds before turning it off.
Avoid switching on/off too frequently.
[ NOTE ]
The filter element will be wet after liquids have been
vacuumed.
A wet filter element can quickly become clogged if the
machine is then used to vacuum dry substances.
For this reason, make sure that the filter element is dry or
replace it with another one before using the machine for dry
materials.
Dust Bag
The machine can be equipped with dust collection bag.
In this case, the machine must be equipped with optional
accessories (depressor and grid).
If the bag is not installed or is installed improperly, it could
create health risks for people exposed.
Paper Bag and Safe Bag for dust collection
The machine can be equipped with dust collection bag.
In this case, the machine must be equipped with a specific
container and a cap on the side.
If the bag is not properly installed, it could create health risks
for people exposed.
The safe bag system is suitable to collect toxic dust to
ensure that the user does not come into contact with the
product.
Longopac
bag for dust collection
®
The machine can be equipped with dust collection bag.
In this case, the material is discharged by gravity when the
vacuuming stops. The Longopac® bag can be cut, sealed or
closed to the size required.
If the bag is not properly installed, it could create health risks
for people exposed.
Replacement of dust bags
Before proceeding with these operations, turn off
the machine and remove the plug from the power
socket.
These operations can only be carried out by trained
and qualified personnel who must wear adequate
clothing, in compliance with the laws in force.
In case of hazardous and/or harmful dust, use only
the bags recommended by the manufacturer (see
"Recommended spare parts").
The bag must only be disposed of by qualified
personnel and in compliance with the laws in force.
Use only original Nilfisk bags.
Only use bags suitable for the machine class you
are using.
Take care not to raise dust during this operation. Wear
a P3 mask and other protective clothing plus protective
gloves (PPE) suited to the hazardous nature of the dust
collected, refer to the laws in force.