Instruction Manual MAP 1
_______________________________________________________________________________________________________________________
Attention
The crimping process can be interrupted at any moment by releasing the trigger.
Attention
Make sure that the locking pin (Pos. 4) is completely pushed in and safely engaged.
Attention
The assembly of gas pipes in gas distribution lines is prohibited unless the system
provider gives an explicit permission to use this tool on special gas fittings.
Attention
The user has to check by optical means whether the pressing jaws are completely
closed.
Attention
If a pressing cycle has been interrupted the fitting has to be either dismantled or
pressed a second time.
The user needs to make sure that the pressing jaws are completely closed and that there are no
foreign objects (e.g. plaster or stone fractions) between the pressing jaws.
By sliding the retract slide (Pos.-No. 2) in the direction of the battery (Pos.-No. 5) the dies can
be retracted in case of an error or emergency. (picture 5 Pos B)
page 28